Literature DB >> 25582413

Well-defined and high resolution Pt nanowire arrays for a high performance hydrogen sensor by a surface scattering phenomenon.

Hae-Wook Yoo1, Soo-Yeon Cho, Hwan-Jin Jeon, Hee-Tae Jung.   

Abstract

Developing hydrogen (H2) sensors with a high sensitivity, rapid response, long-term stability, and high throughput is one of the critical issues in energy and environmental technology [Hübert et al. Sens. Actuators, B 2011, 157, 329]. To date, H2 sensors have been mainly developed using palladium (Pd) as the channel material because of its high selectivity and strong affinity to the H2 molecule [(Xu et al. Appl. Phys. Lett. 2005, 86, 203104), (Offermans et al. Appl. Phys. Lett. 2009, 94, 223110), (Yang et al. Nano Lett. 2009, 9, 2177), (Yang et al. ACS Nano 2010, 4, 5233), and (Zou et al. Chem. Commun. 2012, 48, 1033)]. Despite significant progress in this area, Pd based H2 sensors suffer from fractures on their structure due to hydrogen adsorption induced volumetric swelling during the α → β phase transition, leading to poor long-term stability and reliability [(Favier et al. Science 2001, 293, 2227), (Walter et al. Microelectron. Eng. 2002, 61–62, 555), and (Walter et al. Anal. Chem. 2002, 74, 1546)]. In this study, we developed a platinum (Pt) nanostructure based H2 sensor that avoids the stability limitations of Pd based sensors. This sensor exhibited an excellent sensing performance, low limit of detection (LOD, 1 ppm), reproducibility, and good recovery behavior at room temperature. This Pt based H2 sensor relies on a highly periodic, small cross sectional dimension (10–40 nm) and a well-defined configuration of Pt nanowire arrays over a large area. The resistance of the Pt nanowire arrays significantly decreased upon exposure to H2 due to reduced electron scattering in the cross section of the hydrogen adsorbed Pt nanowires, as compared to the oxygen terminated original state. Therefore, these well-defined Pt nanowire arrays prepared using advanced lithographic techniques can facilitate the production of high performance H2 sensors.

Entities:  

Year:  2015        PMID: 25582413     DOI: 10.1021/ac504367w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Internal stress induced natural self-chemisorption of ZnO nanostructured films.

Authors:  Po-Wei Chi; Chih-Wei Su; Da-Hua Wei
Journal:  Sci Rep       Date:  2017-02-24       Impact factor: 4.379

2.  Metallic one-dimensional heterostructure for gas molecule sensing.

Authors:  Prabal Dev Bhuyan; Sanjeev K Gupta; Rajeev Ahuja; P N Gajjar
Journal:  Sci Rep       Date:  2021-01-11       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.