Literature DB >> 25579531

A comparison between four immobilization systems for pelvic radiation therapy using CBCT and paired kilovoltage portals based image-guided radiotherapy.

Gagan Saini1, Anchal Aggarwal, Syed Ashraf Jafri, Vineeta Goel, Thomas Ranjitsingh, Ram Munjal, Anil Kumar Anand.   

Abstract

INTRODUCTION: We commonly use 6- and 4-clamped thermoplastic molds (TMs) for rigid immobilization during pelvic radiotherapy (RT), sometimes a vacuum cushion (VC) is also used as leg support with TM. Our objective was to report the setup margins (SMs) associated with the different systems, to analyze whether any of these systems is superior, and to analyze whether any of them showed better reproducibility in any particular direction.
MATERIALS AND METHODS: Retrospective analysis was done by dividing the patients into four groups: 6-clamp with VC (6CVC), 6-clamp without VC (6CNC), 4-clamp with VC (4CVC), and 4-clamp without VC (4CNC). A repeat offline review was done for all patients and errors were tabulated. Statistical methods were then applied.
RESULTS: Total 24 patients had 413 image-guided RT (IGRT) sessions, 312 were cone beam computed tomography scan (CBCT) scans and 101 were paired kilovoltage portals (kVp). There was no statistically significant difference between 6CVC and 6CNC. However, while comparing 4CVC and 4CNC, a statistically significant difference was seen in all directions. VC improved precision in vertical and lateral direction mainly, while the 6-clamped TM improved reproducibility in longitudinal direction.
CONCLUSIONS: SM was low for all the four immobilization systems studied. There is no added benefit of using a VC with 6-clamped TM for pelvic RT. Use of a VC is recommended with 4-clamped TM to improve overall reproducibility. 6-clamped TM helps keep the errors low.

Entities:  

Mesh:

Year:  2014        PMID: 25579531     DOI: 10.4103/0973-1482.138026

Source DB:  PubMed          Journal:  J Cancer Res Ther        ISSN: 1998-4138            Impact factor:   1.805


  3 in total

1.  Long-time clinical experience in patient setup for several particle therapy clinical indications: management of patient positioning and evaluation of setup reproducibility and stability.

Authors:  Rosalinda Ricotti; Andrea Pella; Barbara Tagaste; Giovanni Elisei; Giulia Fontana; Maria Bonora; Mario Ciocca; Francesca Valvo; Roberto Orecchia; Guido Baroni
Journal:  Br J Radiol       Date:  2019-11-14       Impact factor: 3.629

2.  Immobilization versus no immobilization for pelvic external beam radiotherapy.

Authors:  Avinash H Udayashankar; Shibina Noorjahan; Nirmala Srikantia; K Ravindra Babu; Sandeep Muzumder
Journal:  Rep Pract Oncol Radiother       Date:  2018-05-17

3.  MRI quantification of pancreas motion as a function of patient setup for particle therapy -a preliminary study.

Authors:  Giulia Fontana; Marco Riboldi; Chiara Gianoli; Cezarina I Chirvase; Gaetano Villa; Chiara Paganelli; Paul E Summers; Barbara Tagaste; Andrea Pella; Piero Fossati; Mario Ciocca; Guido Baroni; Francesca Valvo; Roberto Orecchia
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.