Literature DB >> 25579461

Isothermal circular-strand-displacement polymerization of DNA and microRNA in digital microfluidic devices.

Maria Chiara Giuffrida1, Laura Maria Zanoli, Roberta D'Agata, Alessia Finotti, Roberto Gambari, Giuseppe Spoto.   

Abstract

Nucleic-acid amplification is a crucial step in nucleic-acid-sequence-detection assays. The use of digital microfluidic devices to miniaturize amplification techniques reduces the required sample volume and the analysis time and offers new possibilities for process automation and integration in a single device. The recently introduced droplet polymerase-chain-reaction (PCR) amplification methods require repeated cycles of two or three temperature-dependent steps during the amplification of the nucleic-acid target sequence. In contrast, low-temperature isothermal-amplification methods have no need for thermal cycling, thus requiring simplified microfluidic-device features. Here, the combined use of digital microfluidics and molecular-beacon (MB)-assisted isothermal circular-strand-displacement polymerization (ICSDP) to detect microRNA-210 sequences is described. MicroRNA-210 has been described as the most consistently and predominantly upregulated hypoxia-inducible factor. The nmol L(-1)-pmol L(-1) detection capabilities of the method were first tested by targeting single-stranded DNA sequences from the genetically modified Roundup Ready soybean. The ability of the droplet-ICSDP method to discriminate between full-matched, single-mismatched, and unrelated sequences was also investigated. The detection of a range of nmol L(-1)-pmol L(-1) microRNA-210 solutions compartmentalized in nanoliter-sized droplets was performed, establishing the ability of the method to detect as little as 10(-18) mol of microRNA target sequences compartmentalized in 20 nL droplets. The suitability of the method for biological samples was tested by detecting microRNA-210 from transfected K562 cells.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25579461     DOI: 10.1007/s00216-014-8405-4

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  9 in total

Review 1.  Microfluidics for detection of exosomes and microRNAs in cancer: State of the art.

Authors:  Seyed Mojtaba Mousavi; Seyed Mohammad Amin Mahdian; Mohammad Saeid Ebrahimi; Mohammad Taghizadieh; Massoud Vosough; Javid Sadri Nahand; Saereh Hosseindoost; Nasim Vousooghi; Hamid Akbari Javar; Bagher Larijani; Mahmoud Reza Hadjighassem; Neda Rahimian; Michael R Hamblin; Hamed Mirzaei
Journal:  Mol Ther Nucleic Acids       Date:  2022-04-27       Impact factor: 10.183

2.  miRNA143 Induces K562 Cell Apoptosis Through Downregulating BCR-ABL.

Authors:  Bing Liang; Yanbin Song; Wenling Zheng; Wenli Ma
Journal:  Med Sci Monit       Date:  2016-08-05

3.  Four-Analog Computation Based on DNA Strand Displacement.

Authors:  Chengye Zou; Xiaopeng Wei; Qiang Zhang; Chanjuan Liu; Changjun Zhou; Yuan Liu
Journal:  ACS Omega       Date:  2017-08-02

4.  Liquid biopsy in mice bearing colorectal carcinoma xenografts: gateways regulating the levels of circulating tumor DNA (ctDNA) and miRNA (ctmiRNA).

Authors:  Jessica Gasparello; Matteo Allegretti; Elisa Tremante; Enrica Fabbri; Carla Azzurra Amoreo; Paolo Romania; Elisa Melucci; Katia Messana; Monica Borgatti; Patrizio Giacomini; Roberto Gambari; Alessia Finotti
Journal:  J Exp Clin Cancer Res       Date:  2018-06-26

Review 5.  Peptide Nucleic Acid-Based Biosensors for Cancer Diagnosis.

Authors:  Roberta D'Agata; Maria Chiara Giuffrida; Giuseppe Spoto
Journal:  Molecules       Date:  2017-11-11       Impact factor: 4.411

6.  Isothermal circular strand displacement-based assay for microRNA detection in liquid biopsy.

Authors:  Noemi Bellassai; Roberta D'Agata; Giuseppe Spoto
Journal:  Anal Bioanal Chem       Date:  2022-07-26       Impact factor: 4.478

7.  Picoliter Well Array Chip-Based Digital Recombinase Polymerase Amplification for Absolute Quantification of Nucleic Acids.

Authors:  Zhao Li; Yong Liu; Qingquan Wei; Yuanjie Liu; Wenwen Liu; Xuelian Zhang; Yude Yu
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

Review 8.  Liquid biopsy and PCR-free ultrasensitive detection systems in oncology (Review).

Authors:  Alessia Finotti; Matteo Allegretti; Jessica Gasparello; Patrizio Giacomini; Demetrios A Spandidos; Giuseppe Spoto; Roberto Gambari
Journal:  Int J Oncol       Date:  2018-08-06       Impact factor: 5.650

Review 9.  Novel nucleic acid origami structures and conventional molecular beacon-based platforms: a comparison in biosensing applications.

Authors:  Noemi Bellassai; Roberta D'Agata; Giuseppe Spoto
Journal:  Anal Bioanal Chem       Date:  2021-04-06       Impact factor: 4.142

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.