Linguine sign in musculoskeletal imaging: calf silicone implant rupture.

Dennis Duryea1, Jonelle Petscavage-Thomas, Elizabeth E Frauenhoffer, Eric A Walker.   

Abstract

Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25577259     DOI: 10.1007/s00256-014-2091-3

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  9 in total

1.  Linguine sign.

Authors:  A Safvi
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

2.  Calf implants: a 25-year experience and an anatomical review.

Authors:  Jose Abel de la Peña-Salcedo; Miguel Angel Soto-Miranda; Jose Fernando Lopez-Salguero
Journal:  Aesthetic Plast Surg       Date:  2011-09-30       Impact factor: 2.326

3.  Intracapsular implant rupture: MR findings of incomplete shell collapse.

Authors:  M S Soo; P J Kornguth; R Walsh; C Elenberger; G S Georgiade; D DeLong; C E Spritzer
Journal:  J Magn Reson Imaging       Date:  1997 Jul-Aug       Impact factor: 4.813

Review 4.  MR evaluation of breast implants.

Authors:  Michael S Middleton
Journal:  Radiol Clin North Am       Date:  2014-05       Impact factor: 2.303

5.  Bilateral calf augmentation for aesthetic purposes.

Authors:  Luiz Haroldo Pereira; Beatriz Nicaretta; Aris Sterodimas
Journal:  Aesthetic Plast Surg       Date:  2011-08-19       Impact factor: 2.326

6.  Calf augmentation and restoration.

Authors:  Igor Niechajev
Journal:  Plast Reconstr Surg       Date:  2005-07       Impact factor: 4.730

7.  Calf augmentation--a preliminary report.

Authors:  L N Carlsen
Journal:  Ann Plast Surg       Date:  1979-06       Impact factor: 1.539

8.  Breast implants, common complications, and concurrent breast disease.

Authors:  B G Steinbach; N S Hardt; P L Abbitt; L Lanier; H H Caffee
Journal:  Radiographics       Date:  1993-01       Impact factor: 5.333

9.  Imaging of breast implants-a pictorial review.

Authors:  Sergi Juanpere; Elsa Perez; Oscar Huc; Naiara Motos; Josep Pont; Salvador Pedraza
Journal:  Insights Imaging       Date:  2011-08-07
  9 in total
  2 in total

1.  Capsular Contracture after Calf Augmentation with Silicone Implant Insertion.

Authors:  Bommie Florence Seo; Jong Yun Choi; Jimin Kim; Deuk Young Oh
Journal:  Arch Plast Surg       Date:  2015-09-15

2.  Calf Augmentation Implant Disruption Following a Tibial Plateau Fracture Fixation: An Extremely Rare Complication.

Authors:  Robinson E Pires; Gustavo Waldolato; Egidio O Santana Jr; André Wajnsztejn; Pedro J Labronici; Vincenzo Giordano
Journal:  J Orthop Case Rep       Date:  2019
  2 in total