Literature DB >> 25577241

Plate fixation of extra-articular fractures of the proximal phalanx: do new implants cause less problems?

Pascale Brei-Thoma1, Esther Vögelin, Torsten Franz.   

Abstract

BACKGROUND: Limited range of finger motion is a frequent complication after plate fixation of phalangeal fractures. The purpose of this study was to evaluate the results of plate fixation of extra-articular fractures of the proximal phalanx using current low-profile mini-fragment-systems.
METHODS: From 2006 to 2012, 32 patients with 36 extra-articular fractures of the proximal phalanx of the triphalangeal fingers were treated with open reduction and plate fixation (ORPF) using 1.2 and 1.5 mm mini-fragment systems. Patients presenting with open fractures grade 2 and 3 or relevant laceration of adjacent structures were excluded from the study. We retrospectively evaluated the rate of mal-union or non-union after ORPF, the need for revision surgery, for plate removal, and for tenolysis. Data were analyzed for further complications with regard to infections or complex regional pain syndrome (CRPS).
RESULTS: No infections were noted. Five patients developed transient symptoms of CRPS. Six weeks postoperatively, total active finger motion (TAM) averaged 183°, and all 32 patients underwent formal hand therapy. At the latest follow-up or at the time of plate removal, respectively, the mean TAM improved to 213°. Extension lag of proximal interphalangeal joints was found in 67 % of all fractured fingers. Secondary surgery was necessary in 14 of 32 patients (2 corrective osteotomies, 12 plate removals including 7 procedures explicitly because of reduced mobility).
CONCLUSIONS: Despite of new implant designs significant problems persist. Adhesions of extensor tendons leading to limited range of finger motion are still the most frequent complications after ORPF of proximal phalangeal fractures, even in absence of significant soft-tissue damage. LEVEL OF EVIDENCE: Therapeutic, Retrospective, Level IV.

Entities:  

Mesh:

Year:  2015        PMID: 25577241     DOI: 10.1007/s00402-015-2155-4

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  14 in total

Review 1.  [Reconstruction of the palmar middle phalangeal base of the finger: Treatment with a hemi-hamate transplant].

Authors:  F Unglaub; C K Spies
Journal:  Unfallchirurg       Date:  2016-02       Impact factor: 1.000

Review 2.  [Percutaneous treatment of unstable fractures of the base of the middle phalanx : Technique according to Hintringer and Ender].

Authors:  S Quadlbauer; C Pezzei; W Hintringer; T Hausner; M Leixnering
Journal:  Oper Orthop Traumatol       Date:  2019-07-25       Impact factor: 1.154

3.  Complications during removal of conventional versus locked compression plates: is there a difference?

Authors:  Hanjo Neumann; Anne Stadler; Hinrich Heuer; Marc Auerswald; Justus Gille; Arndt Peter Schulz; Benjamin Kienast
Journal:  Int Orthop       Date:  2016-12-24       Impact factor: 3.075

Review 4.  [Open reduction and plate/screw osteosynthesis of proximal phalanx fractures].

Authors:  F Unglaub; M F Langer; S Löw; B Hohendorff; C K Spies
Journal:  Oper Orthop Traumatol       Date:  2019-04-12       Impact factor: 1.154

5.  The Use of an Adipofascial Flap to Prevent Extensor Tendon Adhesions After Plating of the Proximal Phalanx of the Fingers: A Comparative Study.

Authors:  Stefano Lucchina; Angelo D'Ambrosio; Cesare Fusetti; Marco Guidi
Journal:  Hand (N Y)       Date:  2020-10-17

6.  Comments on "Complications of Low-Profile Plate Fixation of Phalanx Fractures".

Authors:  Stefano Lucchina; Matteo Meroni; Martin Molitor; Marco Guidi
Journal:  Hand (N Y)       Date:  2021-12-22

Review 7.  Proximal Phalanx Fracture Management.

Authors:  Tim T Lögters; Hannah H Lee; Sebastian Gehrmann; Joachim Windolf; Robert A Kaufmann
Journal:  Hand (N Y)       Date:  2017-10-27

8.  [Corrective osteotomy of the hand].

Authors:  Frank Unglaub; Martin F Langer; Julia M Unglaub; Christian K Spies
Journal:  Unfallchirurg       Date:  2018-08       Impact factor: 1.000

Review 9.  [Fractures of the proximal interphalangeal joint: Diagnostic and operative therapy options].

Authors:  F Unglaub; M F Langer; P Hahn; L P Müller; C Ahrens; C K Spies
Journal:  Unfallchirurg       Date:  2016-02       Impact factor: 1.000

10.  Complications of Low-Profile Plate Fixation of Phalanx Fractures.

Authors:  Evan M Guerrero; Rita E Baumgartner; Andrew E Federer; Suhail K Mithani; David S Ruch; Marc J Richard
Journal:  Hand (N Y)       Date:  2019-06-17
View more