Literature DB >> 2557718

Fracture fixation with biodegradable rods. Forty-one cases of severe ankle fractures.

E Hirvensalo1.   

Abstract

In a prospective study of 41 patients, severe ankle fractures of Lauge-Hansen types SE III-IV, PA III, and PE III-IV were treated by open reduction and internal fixation using biodegradable self-reinforced polyglycolide cylinder-shaped rods. Disruption of the distal tibiofibular syndesmosis and/or fracture of the posterior tibial margin requiring reduction and fixation were the inclusion criteria for the study. The mean follow-up time after operation was 16 (12-32) months. Two failures of fixation necessitated reoperation. A secondary displacement of 1-2 mm of the lateral malleolus occurred in 3 cases. Transient accumulation of soluble polyglycolide mass complicated the course in 3 cases, but did not influence the radiographic or the functional result. Function became good in 30 patients. The advantage of the biodegradable implants is that they do not need to be removed at secondary operations.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2557718     DOI: 10.3109/17453678909150131

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  11 in total

1.  Strength retention of drawn self-reinforced polyglycolide rods and fixation properties of the distal femoral osteotomies with these rods. An experimental study on rats.

Authors:  Harri Pihlajamäki; E Antero Mäkelä; Nureddin Ashammakhi; Janne Viljanen; Hannu Pätiälä; Pentti Rokkanen; Timo Pohjonen; Pertti Törmälä; Antti Joukainen
Journal:  J Mater Sci Mater Med       Date:  2002-04       Impact factor: 3.896

2.  Absorbable polyglycolide pins in fixation of displaced fractures of the radial head.

Authors:  E Hirvensalo; O Böstman; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

3.  Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment.

Authors:  Panagiotis K Givissis; Stavros I Stavridis; Panayiotis J Papagelopoulos; Petros D Antonarakos; Anastasios G Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-05-15       Impact factor: 4.176

4.  Intramedullary fixation of cortical bone osteotomies with self-reinforced polylactic rods in rabbits.

Authors:  A Majola; S Vainionpää; K Vihtonen; J Vasenius; P Törmälä; P Rokkanen
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

5.  Fixation of subcapital femoral osteotomies by poly-L-lactic acid pins. An experimental study in sheep.

Authors:  J Vasenius; O Laitinen; T Pohjonen; S Vainionpää; P Törmälä; P Rokkanen
Journal:  Int Orthop       Date:  1993       Impact factor: 3.075

6.  The use of T-LCP (locking compression plate) for the treatment of the lateral malleolar fractures.

Authors:  Hak Jun Kim; Jong-Keon Oh; Jin-Ho Hwang; Young Hwan Park
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-02-07

Review 7.  Biodegradable implants in traumatology: a review on the state-of-the-art.

Authors:  G O Hofmann
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

8.  Bioabsorbable osteosynthetic implants of ultra high strength poly-L-lactide. A clinical study.

Authors:  T Yamamuro; Y Matsusue; A Uchida; K Shimada; E Shimozaki; K Kitaoka
Journal:  Int Orthop       Date:  1994       Impact factor: 3.075

9.  Absorbable self-reinforced polylactide (SR-PLLA) rods vs rigid rods (K-wire) in spinal fusion: an experimental study in rabbits.

Authors:  Murat Bezer; Yakup Yildirim; Bülent Erol; Osman Güven
Journal:  Eur Spine J       Date:  2004-09-18       Impact factor: 3.134

10.  [Immobilization and early mobilization of malleolar fractures after osteosynthesis with resorbable bone screws].

Authors:  E K Partio
Journal:  Unfallchirurgie       Date:  1992-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.