Literature DB >> 25575197

Effect of Desensitizing Agents on the Bond Strength of Mild and Strong Self-etching Adhesives.

C Sabatini, Z Wu.   

Abstract

BACKGROUND: Desensitizing agents are used, almost as routine practice, in many adhesive restorative procedures. There is still debate as to their effect in dentin bonding, particularly with self-etching adhesives. The present study aimed to evaluate the effect of different desensitizing agents on the bond strength of mild and strong self-etching adhesive systems to dentin.
MATERIALS AND METHODS: One hundred twenty recently extracted, noncarious human molars were used to obtain superficial dentin substrate for bonding. No desensitizer was used in the control groups. The experimental groups were pretreated with Gluma Desensitizer, MicroPrime B, and Dentin Desensitizer immediately prior to bonding with self-etching adhesives Optibond XTR, Xeno IV, and iBond. A bonding jig was used to fabricate composite cylinders, which were stored for either 24 hours or three months, after which the shear bond strength (SBS) was evaluated using a notched-edge testing device at a crosshead speed of 1 mm/min. Failure mode distribution was also evaluated at 24 hours and three months. A two-way analysis of variance, Tukey test, and Student t-test, with a significance level of p<0.05, were used for data analysis.
RESULTS: At 24 hours, there was no significant difference in SBS when the same adhesive was used with any of the experimental desensitizing agents compared with the control group without desensitizer. However, at three months, Dentin Desensitizer bonded with Optibond XTR demonstrated significantly lower SBS (p<0.001), while Gluma bonded with iBond showed significantly higher SBS values (p=0.034) relative to their corresponding control group. Only MicroPrime B bonded with Xeno IV and iBond with no desensitizer demonstrated a significant reduction in SBS after three months (p=0.034 and p=0.002, respectively). The most prevalent type of failure was adhesive.
CONCLUSION: Desensitizing agents can be used in combination with self-etching adhesives to control hypersensitivity without adversely affecting their bond strength to dentin.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25575197     DOI: 10.2341/14-190-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Microleakage in Class V Composite Restorations after Desensitizing Surface Treatment with Er:YAG and CO2 Lasers.

Authors:  Hamid Reza Mozaffari; Alireza Ehteshami; Farshad Zallaghi; Nasim Chiniforush; Zohreh Moradi
Journal:  Laser Ther       Date:  2016-12-30

2.  Effect of Nd:YAG laser irradiation, used as a desensitizing strategy, on bond strength to simulated hypersensitive dentin.

Authors:  Karin Landmayer; Juliana Costa Veiga da Silva; Brunna Haddad Anhesini; Bruna de Oliveira Iatarola; Ana Cecília Correa Aranha; Luciana Fávaro Francisconi-Dos-Rios
Journal:  Clin Oral Investig       Date:  2022-01-29       Impact factor: 3.573

3.  In Vitro Comparative Evaluation of Newly Produced Desensitizer, Chlorhexidine and Gluma on Bond Strength and Bond Longevity of Composite to Dentin.

Authors:  Reza Davalloo; Seyedeh Maryam Tavangar; Heshmatollah Ebrahimi; Farideh Darabi; Shima Mahmoudi
Journal:  J Dent (Shiraz)       Date:  2020-06

4.  Influences of desensitizing agents on bond strength of etch-and-rinse and self-etch adhesive system to dentin.

Authors:  Nivedha Viswanath; Anand Sherwood Inbaraj; Bennett Tochukwu Amaechi; Geeth Deepika Gandhi; Rathna Piriyanga Subramani
Journal:  J Conserv Dent       Date:  2021-02-10

5.  Influence of desensitizing agents in management of noncarious cervical lesion and bonded restorations: A preliminary 12-week report.

Authors:  J Joyson Joe Asir; I Anand Sherwood; Bennett T Amaechi; M Vaanjay; S Swathipriyadarshini; P Ernest Prince
Journal:  J Conserv Dent       Date:  2021-01-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.