Literature DB >> 25573445

Outcomes following pacemaker implantation after transcatheter aortic valve implantation with CoreValve(®) devices: Results from the FRANCE 2 Registry.

Gauthier Mouillet1, Nicolas Lellouche1, Masanori Yamamoto1, Atsushi Oguri1, Jean-Luc Dubois-Rande1, Eric Van Belle2, Martine Gilard3, Marc Laskar4, Emmanuel Teiger1.   

Abstract

AIMS: Permanent pacemaker (PPM) implantation following high-degree atrioventricular block is frequently required after transcatheter aortic valve implantation (TAVI) using CoreValve(®) . Recent improvement of the delivery system (CoreValve Accutrak(®) ) aimed to ease delivery and reduce the PPM rate. Our study evaluated the incidences of PPM implantation following use of CoreValve(®) or CoreValve Accutrak(®) and the clinical outcome of these patients. METHODS AND
RESULTS: A total of 883 patients (82 ± 7 years; 41.3% female) with severe symptomatic aortic stenosis and self-expanding bioprosthesis implantation were included between January 2010 and October 2011 in 29 centers from the FRANCE 2 Registry. Follow-up data were available in 833 patients. CoreValve(®) and CoreValve Accutrak(®) were used in 343 (41.2%) and 490 (58.8%) patients, respectively. During a mean follow-up of 242 ± 179 days, all-cause mortality was similar in patients with versus without PPM implantation (16.3 vs. 16.9%, P = 0.832).There was no significant difference in the PPM incidence in CoreValve(®) and CoreValve Accutrak(®) patients (30.4% vs. 27.5%, P = 0.846).
CONCLUSION: PPM implantation remained frequent after TAVI using CoreValve Accutrak(®) . All-cause mortality was similar in patients with or without PPM implantation. The new device failed to show a significant decrease in PPM implantation incidence after TAVI.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic valve stenosis; pacemaker; transcatheter aortic valve implantation

Mesh:

Year:  2015        PMID: 25573445     DOI: 10.1002/ccd.25818

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  11 in total

1.  In-hospital mortality in propensity-score matched low-risk patients undergoing routine isolated surgical or transfemoral transcatheter aortic valve replacement in 2014 in Germany.

Authors:  Christian Frerker; Kurt Bestehorn; Michael Schlüter; Maike Bestehorn; Christian W Hamm; Helge Möllmann; Hugo A Katus; Karl-Heinz Kuck
Journal:  Clin Res Cardiol       Date:  2017-03-10       Impact factor: 5.460

2.  Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve.

Authors:  Birgid Gonska; Julia Seeger; Mirjam Keßler; Alexander von Keil; Wolfgang Rottbauer; Jochen Wöhrle
Journal:  Clin Res Cardiol       Date:  2017-03-10       Impact factor: 5.460

3.  Mid- to Long-Term Clinical and Echocardiographic Effects of Post-procedural Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Shun Xu; Enrui Zhang; Zhiyong Qian; Jinyu Sun; Fengwei Zou; Yao Wang; Xiaofeng Hou; Jiangang Zou
Journal:  Front Cardiovasc Med       Date:  2022-06-28

4.  Short-term pacemaker dependency after transcatheter aortic valve implantation.

Authors:  Christiana Schernthaner; Johannes Kraus; Franz Danmayr; Matthias Hammerer; Jens Schneider; Uta C Hoppe; Bernhard Strohmer
Journal:  Wien Klin Wochenschr       Date:  2016-01-08       Impact factor: 1.704

5.  Impact of postprocedural permanent pacemaker implantation on clinical outcomes after transcatheter aortic valve replacement: a systematic review and meta-analysis.

Authors:  Ziwei Xi; Tong Liu; Jing Liang; Yu-Jie Zhou; Wei Liu
Journal:  J Thorac Dis       Date:  2019-12       Impact factor: 2.895

6.  Early- and mid-term outcomes after transcatheter aortic valve implantation. Data from a single-center registry.

Authors:  Maciej Bagienski; Pawel Kleczynski; Artur Dziewierz; Lukasz Rzeszutko; Danuta Sorysz; Jaroslaw Trebacz; Robert Sobczynski; Marek Tomala; Maciej Stapor; Andrzej Gackowski; Dariusz Dudek
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-05-11       Impact factor: 1.426

Review 7.  Rate and Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Current Status.

Authors:  Eleonora Russo; Domenico R Potenza; Michela Casella; Raimondo Massaro; Giulio Russo; Maurizio Braccio; Antonio Dello Russo; Mauro Cassese
Journal:  Curr Cardiol Rev       Date:  2019

8.  Geriatric issues in patients with or being considered for implanted cardiac rhythm devices: a case-based review.

Authors:  Michael A Chen
Journal:  J Geriatr Cardiol       Date:  2020-11-28       Impact factor: 3.327

9.  Influence of permanent pacemaker implantation after transcatheter aortic valve implantation with new-generation devices.

Authors:  B Gonska; M Keßler; J Wöhrle; W Rottbauer; J Seeger
Journal:  Neth Heart J       Date:  2018-12       Impact factor: 2.380

10.  Association of Clinical and Economic Outcomes With Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement.

Authors:  Talal Aljabbary; Feng Qiu; Shannon Masih; Jiming Fang; Gabby Elbaz-Greener; Peter C Austin; Josep Rodés-Cabau; Dennis T Ko; Sheldon Singh; Harindra C Wijeysundera
Journal:  JAMA Netw Open       Date:  2018-05-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.