Literature DB >> 25571430

A cascaded two-step Kalman filter for estimation of human body segment orientation using MEMS-IMU.

S Zihajehzadeh, D Loh, M Lee, R Hoskinson, E J Park.   

Abstract

Orientation of human body segments is an important quantity in many biomechanical analyses. To get robust and drift-free 3-D orientation, raw data from miniature body worn MEMS-based inertial measurement units (IMU) should be blended in a Kalman filter. Aiming at less computational cost, this work presents a novel cascaded two-step Kalman filter orientation estimation algorithm. Tilt angles are estimated in the first step of the proposed cascaded Kalman filter. The estimated tilt angles are passed to the second step of the filter for yaw angle calculation. The orientation results are benchmarked against the ones from a highly accurate tactical grade IMU. Experimental results reveal that the proposed algorithm provides robust orientation estimation in both kinematically and magnetically disturbed conditions.

Entities:  

Mesh:

Year:  2014        PMID: 25571430     DOI: 10.1109/EMBC.2014.6945062

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  An emerging technology for the identification and characterization of postural-dependent obstructive sleep apnea.

Authors:  Albert Tate; Jennifer Walsh; Veena Kurup; Bindiya Shenoy; Dwayne Mann; Craig Freakley; Peter Eastwood; Philip Terrill
Journal:  J Clin Sleep Med       Date:  2020-01-13       Impact factor: 4.062

2.  Regression Model-Based Walking Speed Estimation Using Wrist-Worn Inertial Sensor.

Authors:  Shaghayegh Zihajehzadeh; Edward J Park
Journal:  PLoS One       Date:  2016-10-20       Impact factor: 3.240

3.  Validation of Novel Relative Orientation and Inertial Sensor-to-Segment Alignment Algorithms for Estimating 3D Hip Joint Angles.

Authors:  Lukas Adamowicz; Reed D Gurchiek; Jonathan Ferri; Anna T Ursiny; Niccolo Fiorentino; Ryan S McGinnis
Journal:  Sensors (Basel)       Date:  2019-11-24       Impact factor: 3.576

4.  A Wearable System Based on Multiple Magnetic and Inertial Measurement Units for Spine Mobility Assessment: A Reliability Study for the Evaluation of Ankylosing Spondylitis.

Authors:  Adriana Martínez-Hernández; Juan S Perez-Lomelí; Ruben Burgos-Vargas; Miguel A Padilla-Castañeda
Journal:  Sensors (Basel)       Date:  2022-02-10       Impact factor: 3.576

5.  Mechanical Design and Assessment of a Low-Cost 7-DOF Prosthetic Arm for Shoulder Disarticulation.

Authors:  José-Alfredo Leal-Naranjo; Christopher-René Torres-San Miguel; Marco Ceccarelli; Horacio Rostro-Gonzalez
Journal:  Appl Bionics Biomech       Date:  2018-09-03       Impact factor: 1.781

  5 in total