Literature DB >> 25571364

A low-power, time-division-multiplexed vector matrix-multiplier for a vestibular prosthesis.

Hakan Töreyin, Pamela T Bhatti.   

Abstract

A custom analog vector matrix multiplier (VMM) for a vestibular prosthesis is reported. The VMM functions to reduce misalignment between implanted angular rate sensors and associated peripheral sense organs and precompensate for spurious electrical stimulation of vestibular neurons. Operating in the CMOS subthreshold region, the VMM performs a 3-by-3 vector matrix multiplication of rate sensor outputs, magnitude <; ±250 mV, and bandwidth <; 1.25 kHz. To reduce susceptibility to device mismatches, time-division-multiplexed multiplication is employed requiring 727 μs for a complete operation cycle. Fabricated with TSMC 0.35 μm CMOS technology, the footprint is 1523 μm × 1548 μm and consumes 5.37 μW of power.

Entities:  

Mesh:

Year:  2014        PMID: 25571364      PMCID: PMC5889307          DOI: 10.1109/EMBC.2014.6944996

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  7 in total

1.  Directional coding of three-dimensional movements by the vestibular semicircular canals.

Authors:  R D Rabbitt
Journal:  Biol Cybern       Date:  1999-06       Impact factor: 2.086

2.  Vestibulo-ocular reflex responses to a multichannel vestibular prosthesis incorporating a 3D coordinate transformation for correction of misalignment.

Authors:  Gene Y Fridman; Natan S Davidovics; Chenkai Dai; Americo A Migliaccio; Charles C Della Santina
Journal:  J Assoc Res Otolaryngol       Date:  2010-02-23

3.  The vestibular nerve of the chinchilla. II. Relation between afferent response properties and peripheral innervation patterns in the semicircular canals.

Authors:  R A Baird; G Desmadryl; C Fernández; J M Goldberg
Journal:  J Neurophysiol       Date:  1988-07       Impact factor: 2.714

4.  A field-programmable analog array development platform for vestibular prosthesis signal processing.

Authors:  Hakan Töreyin; Pamela Bhatti
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2013-06       Impact factor: 3.833

5.  Physiology of peripheral neurons innervating otolith organs of the squirrel monkey. II. Directional selectivity and force-response relations.

Authors:  C Fernández; J M Goldberg
Journal:  J Neurophysiol       Date:  1976-09       Impact factor: 2.714

6.  Electrical stimulation of semicircular canal afferents affects the perception of head orientation.

Authors:  Richard F Lewis; Csilla Haburcakova; Wangsong Gong; Daniel Lee; Daniel Merfeld
Journal:  J Neurosci       Date:  2013-05-29       Impact factor: 6.167

Review 7.  Progress toward development of a multichannel vestibular prosthesis for treatment of bilateral vestibular deficiency.

Authors:  Gene Y Fridman; Charles C Della Santina
Journal:  Anat Rec (Hoboken)       Date:  2012-10-08       Impact factor: 2.064

  7 in total
  1 in total

1.  A Low-Power ASIC Signal Processor for a Vestibular Prosthesis.

Authors:  Hakan Töreyin; Pamela T Bhatti
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2016-01-18       Impact factor: 3.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.