Literature DB >> 25571131

The impact of head movements on EEG and contact impedance: an adaptive filtering solution for motion artifact reduction.

Vojkan Mihajlovic, Shrishail Patki, Bernard Grundlehner.   

Abstract

Designing and developing a comfortable and convenient EEG system for daily usage that can provide reliable and robust EEG signal, encompasses a number of challenges. Among them, the most ambitious is the reduction of artifacts due to body movements. This paper studies the effect of head movement artifacts on the EEG signal and on the dry electrode-tissue impedance (ETI), monitored continuously using the imec's wireless EEG headset. We have shown that motion artifacts have huge impact on the EEG spectral content in the frequency range lower than 20 Hz. Coherence and spectral analysis revealed that ETI is not capable of describing disturbances at very low frequencies (below 2 Hz). Therefore, we devised a motion artifact reduction (MAR) method that uses a combination of a band-pass filtering and multi-channel adaptive filtering (AF), suitable for real-time MAR. This method was capable of substantially reducing artifacts produced by head movements.

Entities:  

Mesh:

Year:  2014        PMID: 25571131     DOI: 10.1109/EMBC.2014.6944763

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Decoding different working memory states during an operation span task from prefrontal fNIRS signals.

Authors:  Ting Chen; Cui Zhao; Xingyu Pan; Junda Qu; Jing Wei; Chunlin Li; Ying Liang; Xu Zhang
Journal:  Biomed Opt Express       Date:  2021-05-18       Impact factor: 3.732

2.  Adaptive Filtering Improved Apnea Detection Performance Using Tracheal Sounds in Noisy Environment: A Simulation Study.

Authors:  Yanan Wu; Jing Liu; Baolin He; Xiaotong Zhang; Lu Yu
Journal:  Biomed Res Int       Date:  2020-05-21       Impact factor: 3.411

3.  Characterizing and Removing Artifacts Using Dual-Layer EEG during Table Tennis.

Authors:  Amanda Studnicki; Ryan J Downey; Daniel P Ferris
Journal:  Sensors (Basel)       Date:  2022-08-05       Impact factor: 3.847

4.  Effects of Cable Sway, Electrode Surface Area, and Electrode Mass on Electroencephalography Signal Quality during Motion.

Authors:  Evangelia-Regkina Symeonidou; Andrew D Nordin; W David Hairston; Daniel P Ferris
Journal:  Sensors (Basel)       Date:  2018-04-03       Impact factor: 3.576

5.  An EEG Experimental Study Evaluating the Performance of Texas Instruments ADS1299.

Authors:  Usman Rashid; Imran Khan Niazi; Nada Signal; Denise Taylor
Journal:  Sensors (Basel)       Date:  2018-11-01       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.