Literature DB >> 25570384

Real-time processing of fast-scan cyclic voltammetry (FSCV) data using a field-programmable gate array (FPGA).

Bardia Bozorgzadeh, Daniel P Covey, Byron A Heidenreich, Paul A Garris, Pedram Mohseni.   

Abstract

This paper reports the hardware implementation of a digital signal processing (DSP) unit for real-time processing of data obtained by fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM), an electrochemical transduction technique for high-resolution monitoring of brain neurochemistry. Implemented on a field-programmable gate array (FPGA), the DSP unit comprises a decimation filter and an embedded processor to process the oversampled FSCV data and obtain in real time a temporal profile of concentration variation along with a chemical signature to identify the target neurotransmitter. Interfaced with an integrated, FSCV-sensing front-end, the DSP unit can successfully process FSCV data obtained by bolus injection of dopamine in a flow cell as well as electrically evoked, transient dopamine release in the dorsal striatum of an anesthetized rat.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25570384     DOI: 10.1109/EMBC.2014.6944016

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  2 in total

1.  Neurochemostat: A Neural Interface SoC With Integrated Chemometrics for Closed-Loop Regulation of Brain Dopamine.

Authors:  Bardia Bozorgzadeh; Douglas R Schuweiler; Martin J Bobak; Paul A Garris; Pedram Mohseni
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2015-09-16       Impact factor: 3.833

Review 2.  Closed-Loop Implantable Therapeutic Neuromodulation Systems Based on Neurochemical Monitoring.

Authors:  Khalid B Mirza; Caroline T Golden; Konstantin Nikolic; Christofer Toumazou
Journal:  Front Neurosci       Date:  2019-08-20       Impact factor: 4.677

  2 in total