Assessing the challenges of a pulse wave velocity based blood pressure measurement in surgical patients.

Guanqun Zhang, Scott A McCombie, Richard Greenstein, Devin B McCombie.   

Abstract

Development of a continuous noninvasive blood pressure (cNIBP) monitor that is unobtrusive to patients is an attractive alternative to the cuff based measurements performed on medical-surgical floors in the hospital. Pulse wave velocity (PWV) provides a means to continuously monitor blood pressure in these patients. However, a PWV based cNIBP monitor faces a number of challenges in order to accurately measure blood pressure. In our study, we investigated some of the challenges faced by a body-worn cNIBP monitor (i.e. ViSi Mobile) on data collected on patients undergoing surgery. Results indicated that 1) pulse arrival time (PAT) values from ViSi Mobile were well correlated with PAT values obtained from an invasive reference; 2) the reciprocal of the PAT measurements were linearly correlated with blood pressure but the calibration curve was altered by administration of certain vasoactive substances; and 3) there are deterministic correlations between systolic pressure, diastolic pressure and the corresponding mean arterial pressure over a wide range of blood pressure values.

Entities:  

Mesh:

Year:  2014        PMID: 25570024     DOI: 10.1109/EMBC.2014.6943656

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Automated closed-loop resuscitation of multiple hemorrhages: a comparison between fuzzy logic and decision table controllers in a sheep model.

Authors:  Nicole Ribeiro Marques; Brent J Ford; Muzna N Khan; Michael Kinsky; Donald J Deyo; William J Mileski; Hao Ying; George C Kramer
Journal:  Disaster Mil Med       Date:  2017-01-09

2.  Aging steepens the slope of power spectrum density of 30-minute continuous blood pressure recording in healthy human subjects.

Authors:  Jumpei Mano; Keita Saku; Hiroyuki Kinoshita; Hiroshi Mannoji; Shigehiko Kanaya; Kenji Sunagawa
Journal:  PLoS One       Date:  2021-03-18       Impact factor: 3.240

3.  An Arterial Compliance Sensor for Cuffless Blood Pressure Estimation Based on Piezoelectric and Optical Signals.

Authors:  Cheng-Yan Guo; Hao-Ching Chang; Kuan-Jen Wang; Tung-Li Hsieh
Journal:  Micromachines (Basel)       Date:  2022-08-16       Impact factor: 3.523

4.  Hemodynamic monitoring in the era of digital health.

Authors:  Frederic Michard
Journal:  Ann Intensive Care       Date:  2016-02-17       Impact factor: 6.925

Review 5.  Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

Authors:  Kaylie Welykholowa; Manish Hosanee; Gabriel Chan; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-04-22       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.