Literature DB >> 25565078

Do capillary dried blood spot concentrations of gamma-hydroxybutyric acid mirror those in venous blood? A comparative study.

Nele Sadones1, John R H Archer, Ann-Sofie M E Ingels, Paul I Dargan, David M Wood, Michelle Wood, Hugo Neels, Willy E Lambert, Christophe P Stove.   

Abstract

Gamma-hydroxybutyric acid (GHB) is a well-known illicit club and date-rape drug. Dried blood spot (DBS) sampling is a promising alternative for classical venous sampling in cases of (suspected) GHB intoxication since it allows rapid sampling, which is of interest for the extensively metabolized GHB. However, there is limited data if -and how- capillary DBS concentrations correlate with venous concentrations. We conducted a comparative study in 50 patients with suspected GHB intoxication, to determine and to correlate GHB concentrations in venous DBS (vDBS) and capillary DBS (cDBS). This is the first study that evaluates in a large cohort the correlation between capillary and venous concentrations of an illicit drug in real-life samples. Of the 50 paired samples, 7 were excluded: the vDBS concentration was below the LLOQ of 2 µg/mL in 3 cases and 4 samples were excluded after visual inspection of the DBS. Bland-Altman analysis revealed a mean % difference of -2.8% between cDBS and vDBS concentrations, with the zero value included in the 95% confidence interval of the mean difference in GHB concentration. A paired sample t-test confirmed this observation (p = 0.17). Also the requirement for incurred sample reproducibility was fulfilled: for more than two-thirds of the samples the concentrations obtained in cDBS and those in vDBS were within 20% of their mean. Since equivalent concentrations were observed in cDBS and vDBS, blood obtained by fingerprick can be considered a valid alternative for venous blood for GHB determination.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  capillary sampling; dried blood spots (DBS); gamma-hydroxybutyric acid (GHB); gas chromatography-mass spectrometry (GC-MS)

Mesh:

Substances:

Year:  2015        PMID: 25565078     DOI: 10.1002/dta.1760

Source DB:  PubMed          Journal:  Drug Test Anal        ISSN: 1942-7603            Impact factor:   3.345


  1 in total

1.  A 'Dilute and Shoot' Liquid Chromatography-Mass Spectrometry Method for Multiclass Drug Analysis in Pre-Cut Dried Blood Spots.

Authors:  Lucia Mainero Rocca; Nunziata L'Episcopo; Andrea Gordiani; Matteo Vitali; Alessandro Staderini
Journal:  Int J Environ Res Public Health       Date:  2021-03-16       Impact factor: 3.390

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.