Literature DB >> 25564779

Differences between state entropy and bispectral index during analysis of identical electroencephalogram signals: a comparison with two randomised anaesthetic techniques.

Stefanie Pilge1, Matthias Kreuzer, Veliko Karatchiviev, Eberhard F Kochs, Michael Malcharek, Gerhard Schneider.   

Abstract

BACKGROUND: It is claimed that bispectral index (BIS) and state entropy reflect an identical clinical spectrum, the hypnotic component of anaesthesia. So far, it is not known to what extent different devices display similar index values while processing identical electroencephalogram (EEG) signals.
OBJECTIVE: To compare BIS and state entropy during analysis of identical EEG data. Inspection of raw EEG input to detect potential causes of erroneous index calculation.
DESIGN: Offline re-analysis of EEG data from a randomised, single-centre controlled trial using the Entropy Module and an Aspect A-2000 monitor.
SETTING: Klinikum rechts der Isar, Technische Universität München, Munich. PATIENTS: Forty adult patients undergoing elective surgery under general anaesthesia.
INTERVENTIONS: Blocked randomisation of 20 patients per anaesthetic group (sevoflurane/remifentanil or propofol/remifentanil). Isolated forearm technique for differentiation between consciousness and unconsciousness. MAIN OUTCOME MEASURES: Prediction probability (PK) of state entropy to discriminate consciousness from unconsciousness. Correlation and agreement between state entropy and BIS from deep to light hypnosis. Analysis of raw EEG compared with index values that are in conflict with clinical examination, with frequency measures (frequency bands/Spectral Edge Frequency 95) and visual inspection for physiological EEG patterns (e.g. beta or delta arousal), pathophysiological features such as high-frequency signals (electromyogram/high-frequency EEG or eye fluttering/saccades), different types of electro-oculogram or epileptiform EEG and technical artefacts.
RESULTS: PK of state entropy was 0.80 and of BIS 0.84; correlation coefficient of state entropy with BIS 0.78. Nine percent BIS and 14% state entropy values disagreed with clinical examination. Highest incidence of disagreement occurred after state transitions, in particular for state entropy after loss of consciousness during sevoflurane anaesthesia. EEG sequences which led to false 'conscious' index values often showed high-frequency signals and eye blinks. High-frequency EEG/electromyogram signals were pooled because a separation into EEG and fast electro-oculogram, for example eye fluttering or saccades, on the basis of a single EEG channel may not be very reliable. These signals led to higher Spectral Edge Frequency 95 and ratio of relative beta and gamma band power than EEG signals, indicating adequate unconscious classification. The frequency of other artefacts that were assignable, for example technical artefacts, movement artefacts, was negligible and they were excluded from analysis.
CONCLUSION: High-frequency signals and eye blinks may account for index values that falsely indicate consciousness. Compared with BIS, state entropy showed more false classifications of the clinical state at transition between consciousness and unconsciousness.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25564779     DOI: 10.1097/EJA.0000000000000189

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  5 in total

1.  Reading beyond quantitative electroencephalography-based indices: a case of erroneously high entropy values during ophthalmic surgery.

Authors:  Yuh-Shyan Wu; Po-Nien Chen; Gwo-Ching Sun; Kuang-I Cheng; Zhi-Fu Wu
Journal:  Korean J Anesthesiol       Date:  2021-11-22

2.  Offline comparison of processed electroencephalogram monitors for anaesthetic-induced electroencephalogram changes in older adults.

Authors:  Sarah L Eagleman; Caitlin M Drover; Xi Li; M Bruce MacIver; David R Drover
Journal:  Br J Anaesth       Date:  2021-02-25       Impact factor: 9.166

3.  A Comparison of Bispectral Index and Entropy During Sevoflurane Anesthesia Induction in Children with and without Diplegic Cerebral Palsy.

Authors:  Young Sung Kim; Young Ju Won; Hyerim Jeong; Byung Gun Lim; Myoung Hoon Kong; Il Ok Lee
Journal:  Entropy (Basel)       Date:  2019-05-15       Impact factor: 2.524

4.  PRISMA: accuracy of response entropy and bispectral index to predict the transition of consciousness during sevoflurane anesthesia: A systematic review and meta-analysis.

Authors:  Tao Liang; Fan Wu; Baoguo Wang; Feng Mu
Journal:  Medicine (Baltimore)       Date:  2021-04-30       Impact factor: 1.817

5.  Variations in Values of State, Response Entropy and Haemodynamic Parameters Associated with Development of Different Epileptiform Patterns during Volatile Induction of General Anaesthesia with Two Different Anaesthetic Regimens Using Sevoflurane in Comparison with Intravenous Induct: A Comparative Study.

Authors:  Michał Stasiowski; Anna Duława; Izabela Szumera; Radosław Marciniak; Ewa Niewiadomska; Wojciech Kaspera; Lech Krawczyk; Piotr Ładziński; Beniamin Oskar Grabarek; Przemysław Jałowiecki
Journal:  Brain Sci       Date:  2020-06-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.