Literature DB >> 25563525

Effect of osteogenic periosteal distraction by a modified Hyrax device with and without platelet-rich fibrin on bone formation in a rabbit model: a pilot study.

P Pripatnanont1, F Balabid2, S Pongpanich2, S Vongvatcharanon2.   

Abstract

This study evaluated the effect of a modified Hyrax device and platelet-rich fibrin (PRF) on osteogenic periosteal distraction (OPD). Twelve adult male New Zealand white rabbits were separated into two main groups (six in each) according to the duration of the consolidation period (4 or 8 weeks). In each main group, the animals underwent OPD of the left and right sides of the mandible and were divided into four subgroups (three animals per group): device vs. device+PRF, and PRF vs. sham. Radiographic, histological, histomorphometric, and micro-computed tomography (micro-CT) analyses were performed. New bone formation was observed on the lateral and vertical sides of the mandible of all groups. Micro-CT and histomorphometry showed that the device+PRF group presented the highest percentages of bone volume and bone area at 4 weeks (56.67 ± 12.67%, 41.37 ± 7.57%) and at 8 weeks (49.67 ± 8.33%, 55.46 ± 10.67%; significantly higher than the other groups, P<0.001), followed by the device group at 4 weeks (33.00 ± 1.73%, 33.21 ± 11.00%) and at 8 weeks (30.00 ± 3.00%, 23.25 ± 5.46%). In conclusion, the modified Hyrax device was used successfully for OPD in a rabbit model to gain vertical ridge augmentation, and greater bone maturation was achieved with the addition of PRF.
Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Distraction osteogenesis; Histomorphometry; Hyrax device; Micro-CT; Osteogenic periosteal distraction; Platelet-rich fibrin; Rabbit

Mesh:

Substances:

Year:  2015        PMID: 25563525     DOI: 10.1016/j.ijom.2014.12.004

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  7 in total

Review 1.  Application of chemical factors for acceleration of consolidation phase of the distraction osteogenesis: a scoping review.

Authors:  Sadra Mohaghegh; Fatemeh Alirezaei; Nima Ahmadi; Farnaz Kouhestani; Saeed Reza Motamedian
Journal:  Oral Maxillofac Surg       Date:  2022-07-19

Review 2.  Systematic Review and Quality Evaluation Using ARRIVE 2.0 Guidelines on Animal Models Used for Periosteal Distraction Osteogenesis.

Authors:  Mario García-González; Fernando Muñoz; Antonio González-Cantalapiedra; Mónica López-Peña; Nikola Saulacic
Journal:  Animals (Basel)       Date:  2021-04-24       Impact factor: 2.752

Review 3.  Periosteal Distraction Osteogenesis: An Effective Method for Bone Regeneration.

Authors:  Danyang Zhao; Yu Wang; Dong Han
Journal:  Biomed Res Int       Date:  2016-12-18       Impact factor: 3.411

4.  Effects of platelet-rich fibrin on osteogenic differentiation of Schneiderian membrane derived mesenchymal stem cells and bone formation in maxillary sinus.

Authors:  Jia Wang; Yue Sun; Yiping Liu; Jize Yu; Xiaolin Sun; Lin Wang; Yanmin Zhou
Journal:  Cell Commun Signal       Date:  2022-06-15       Impact factor: 7.525

Review 5.  Progress of Periosteal Osteogenesis: The Prospect of In Vivo Bioreactor.

Authors:  Xiaoxue Chen; Baofu Yu; Zi Wang; Qingfeng Li; Chuanchang Dai; Jiao Wei
Journal:  Orthop Surg       Date:  2022-07-06       Impact factor: 2.279

Review 6.  Animal models of vertical bone augmentation (Review).

Authors:  Zepeng Zhang; Yaxin Gan; Yarong Guo; Xuguang Lu; Xianqi Li
Journal:  Exp Ther Med       Date:  2021-06-30       Impact factor: 2.447

Review 7.  Platelet-Rich Fibrin as a Bone Graft Material in Oral and Maxillofacial Bone Regeneration: Classification and Summary for Better Application.

Authors:  Yiping Liu; Xiaolin Sun; Jize Yu; Jia Wang; Peisong Zhai; Siyu Chen; Manxuan Liu; Yanmin Zhou
Journal:  Biomed Res Int       Date:  2019-12-06       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.