Simulation, design, and testing of a high power collimator for the RDS-112 cyclotron.

Johanna L Peeples1, Matthew H Stokely2, Michael C Poorman2, Gerald T Bida3, Bruce W Wieland2.   

Abstract

A high power [F-18] fluoride target package for the RDS-112 cyclotron has been designed, tested, and commercially deployed. The upgrade includes the CF-1000 target, a 1.3kW water target with an established commercial history on RDS-111/Eclipse cyclotrons, and a redesigned collimator with improved heat rejection capabilities. Conjugate heat transfer analyses were employed to both evaluate the existing collimator capabilities and design a suitable high current replacement.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Batch boiling target; Collimator; Cyclotron targetry; Fluorine-18; Positron emission tomography; RDS-112

Mesh:

Substances:

Year:  2014        PMID: 25562677      PMCID: PMC4329277          DOI: 10.1016/j.apradiso.2014.12.028

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  8 in total

1.  A water-cooled spherical niobium target for the production of [18F]fluoride.

Authors:  S K Zeisler; D W Becker; R A Pavan; R Moschel; H Rühle
Journal:  Appl Radiat Isot       Date:  2000-09       Impact factor: 1.513

2.  1999 ICP Distinguished Scientist Award. The history of positron emission tomography.

Authors:  Ronald Nutt
Journal:  Mol Imaging Biol       Date:  2002-01       Impact factor: 3.488

3.  Risks of beryllium disease related to work processes at a metal, alloy, and oxide production plant.

Authors:  K Kreiss; M M Mroz; B Zhen; H Wiedemann; B Barna
Journal:  Occup Environ Med       Date:  1997-08       Impact factor: 4.402

4.  A grid-mounted niobium body target for the production of reactive [18F]fluoride.

Authors:  Jonathon A Nye; Miguel A Avila-Rodriguez; Robert J Nickles
Journal:  Appl Radiat Isot       Date:  2005-12-20       Impact factor: 1.513

5.  Measurement of long lived radioactive impurities retained in the disposable cassettes on the Tracerlab MX system during the production of [18F]FDG.

Authors:  D Ferguson; P Orr; J Gillanders; G Corrigan; C Marshall
Journal:  Appl Radiat Isot       Date:  2011-05-30       Impact factor: 1.513

6.  Thermal performance of batch boiling water targets for 18F production.

Authors:  Johanna L Peeples; Matthew H Stokely; J Michael Doster
Journal:  Appl Radiat Isot       Date:  2011-07-08       Impact factor: 1.513

7.  Assessing the performance and longevity of Nb, Pt, Ta, Ti, Zr, and ZrO₂-sputtered Havar foils for the high-power production of reactive [18F]F by proton irradiation of [18O]H2O.

Authors:  K Gagnon; J S Wilson; E Sant; C J Backhouse; S A McQuarrie
Journal:  Appl Radiat Isot       Date:  2011-02-25       Impact factor: 1.513

8.  Tantalum [18O]water target for the production of [18F]fluoride with high reactivity for the preparation of 2-deoxy-2-[18F]fluoro-D-glucose.

Authors:  N Satyamurthy; Bernard Amarasekera; C William Alvord; Jorge R Barrio; Michael E Phelps
Journal:  Mol Imaging Biol       Date:  2002-01       Impact factor: 3.488