Literature DB >> 25560010

Correlation between two chemiluminescence based assays for quantification of hepatitis B surface antigen in patients with chronic hepatitis B infection.

E Gupta1, P Pandey, A Kumar, M K Sharma, S K Sarin.   

Abstract

PURPOSE: Hepatitis B surface Antigen (HBsAg) is the hallmark in diagnosing hepatitis B virus (HBV) infection. In India many commercial assays are available for detection of HBsAg but very few can measure it quantitatively. The present study presents the comparative evaluation of two methods and their correlation with serum HBsAg in chronic hepatitis B (CHB) patients.
MATERIALS AND METHODS: Consecutive patients of CHB were included and there HBsAg levels were measured by two methods: (i) Elecsys, Roche Diagnostics, a qualitative assay and (ii) Architect, Abbott Diagnostics, a quantitative assay. The HBV DNA was measured by real-time polymerase chain reaction (qPCR).
RESULTS: Total of 136 patients were included in the study and there was a significant overall correlation between both the assays (correlation coefficient [r] = 0.83; P < 0.001). Assays correlated well with each other across all subgroups of CHB: treatment naοve (r = 0.73; P < 0.001, n = 32), on treatment (r = 0.56; P < 0.05, n = 104), hepatitis Be (HBe) antigen positive (r = 0.67; P < 0.001, n = 62) and anti-HBe positive (r = 0.61; P < 0.05, n = 74) group. On correlation with serum HBV DNA, Architect assay demonstrated good correlation (r = 0.73; P < 0.001, n = 136) as compared to the Elecsys assay (r = 0.27; P = 0.068, n = 136). Architect HBsAg QT assay (A1) also correlated well with HBV DNA in the treatment naοve group (r = 0.69; P < 0.001, n = 32).
CONCLUSIONS: Our study hence proved that both the assays are comparable and a simple qualitative assay with in-house modification can be used easily for quatitation of HBsAg in clinical samples.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25560010     DOI: 10.4103/0255-0857.148400

Source DB:  PubMed          Journal:  Indian J Med Microbiol        ISSN: 0255-0857            Impact factor:   0.985


  2 in total

1.  Detection of hepatitis B virus infection: A systematic review.

Authors:  Mallika Ghosh; Srijita Nandi; Shrinwanti Dutta; Malay Kumar Saha
Journal:  World J Hepatol       Date:  2015-10-18

Review 2.  Genosensors as an alternative diagnostic sensing approaches for specific detection of virus species: A review of common techniques and outcomes.

Authors:  Abouzar Babaei; Amir Pouremamali; Nastaran Rafiee; Hessamaddin Sohrabi; Ahad Mokhtarzadeh; Miguel de la Guardia
Journal:  Trends Analyt Chem       Date:  2022-05-19       Impact factor: 14.908