Literature DB >> 25557919

Bioabsorbable versus metallic interference screws in anterior cruciate ligament reconstruction: a systematic review of overlapping meta-analyses.

Randy Mascarenhas1, Bryan M Saltzman2, Eli T Sayegh3, Nikhil N Verma2, Brian J Cole2, Charles Bush-Joseph2, Bernard R Bach2.   

Abstract

PURPOSE: Multiple meta-analyses of randomized controlled trials have been conducted to compare clinical and functional outcomes after anterior cruciate ligament (ACL) reconstruction using metallic interference screw (MIS) versus bioabsorbable interference screw (BIS) fixation, but discrepancies in their findings have prevented a consensus conclusion. The purposes of this study were (1) to conduct a systematic review of meta-analyses comparing MISs and BISs in ACL reconstruction, (2) to provide surgical treatment recommendations for ACL graft fixation based on the highest available evidence, and (3) to propose future research avenues in areas of practice lacking high-level evidence.
METHODS: The literature was systematically reviewed to identify meta-analyses comparing MISs and BISs in ACL reconstruction. Data were extracted for clinical and functional outcomes, and methodologic quality was assessed using the validated Quality of Reporting of Meta-analyses and Oxman-Guyatt systems. To determine which meta-analyses provided the current best available evidence, the Jadad decision algorithm was used.
RESULTS: One Level I and 2 Level II meta-analyses were included. None showed differences between BISs and MISs in validated outcome scores, pivot-shift testing, KT arthrometry (MEDmetric, San Diego, CA), or loss of knee motion. Subgroup analyses found no differences in clinical outcomes or knee stability across biomaterials. All meta-analyses were of high quality according to the Quality of Reporting of Meta-analyses and Oxman-Guyatt systems. Two meta-analyses were determined by the Jadad algorithm to represent the current best available evidence. Both studies showed prolonged knee effusion with BIS use, with 1 also showing an increased incidence of femoral tunnel widening and screw breakage with BIS use.
CONCLUSIONS: Whereas clinical and functional outcomes are similar with MISs and BISs, prolonged knee effusion, femoral tunnel widening, and screw breakage are more common with BIS use. Future cost-effectiveness analyses may help weigh the known advantages of BISs against their costs and adverse-event profile. LEVEL OF EVIDENCE: Level II, systematic review of Level I and II studies.
Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25557919     DOI: 10.1016/j.arthro.2014.11.011

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  18 in total

1.  Risk of Revision Was Not Reduced by a Double-bundle ACL Reconstruction Technique: Results From the Scandinavian Registers.

Authors:  Cathrine Aga; Jüri-Tomas Kartus; Martin Lind; Stein Håkon Låstad Lygre; Lars-Petter Granan; Lars Engebretsen
Journal:  Clin Orthop Relat Res       Date:  2017-10       Impact factor: 4.176

Review 2.  Outcome measures in clinical ACL studies: an analysis of highly cited level I trials.

Authors:  Sufian S Ahmad; Johannes C Meyer; Anna M Krismer; Suhaib S Ahmad; Dimitrios S Evangelopoulos; Sven Hoppe; Sandro Kohl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-14       Impact factor: 4.342

3.  Osteoarthritis in Football.

Authors:  Gian M Salzmann; Stefan Preiss; Marcy Zenobi-Wong; Laurent P Harder; Dirk Maier; Jirí Dvorák
Journal:  Cartilage       Date:  2016-07-08       Impact factor: 4.634

4.  Press-fit fixation in anterior cruciate ligament reconstruction yields low graft failure and revision rates: a systematic review and meta-analysis.

Authors:  Ajaykumar Shanmugaraj; Mathepan Mahendralingam; Chetan Gohal; Nolan Horner; Nicole Simunovic; Volker Musahl; Kristian Samuelsson; Olufemi R Ayeni
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-08-12       Impact factor: 4.342

5.  Interference screw insertion angle has no effect on graft fixation strength for insertional Achilles tendon reconstruction.

Authors:  Ziying Wu; Hongyun Li; Shiyi Chen; Kui Ma; Shengkun Li; Peng Zhang; Yinghui Hua
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-02-14       Impact factor: 4.342

6.  Surgical Predictors of Clinical Outcomes After Revision Anterior Cruciate Ligament Reconstruction.

Authors:  Christina R Allen; Allen F Anderson; Daniel E Cooper; Thomas M DeBerardino; Warren R Dunn; Amanda K Haas; Laura J Huston; Brett Brick A Lantz; Barton Mann; Sam K Nwosu; Kurt P Spindler; Michael J Stuart; Rick W Wright; John P Albright; Annunziato Ned Amendola; Jack T Andrish; Christopher C Annunziata; Robert A Arciero; Bernard R Bach; Champ L Baker; Arthur R Bartolozzi; Keith M Baumgarten; Jeffery R Bechler; Jeffrey H Berg; Geoffrey A Bernas; Stephen F Brockmeier; Robert H Brophy; Charles A Bush-Joseph; J Brad Butler; John D Campbell; James L Carey; James E Carpenter; Brian J Cole; Jonathan M Cooper; Charles L Cox; R Alexander Creighton; Diane L Dahm; Tal S David; David C Flanigan; Robert W Frederick; Theodore J Ganley; Elizabeth A Garofoli; Charles J Gatt; Steven R Gecha; James Robert Giffin; Sharon L Hame; Jo A Hannafin; Christopher D Harner; Norman Lindsay Harris; Keith S Hechtman; Elliott B Hershman; Rudolf G Hoellrich; Timothy M Hosea; David C Johnson; Timothy S Johnson; Morgan H Jones; Christopher C Kaeding; Ganesh V Kamath; Thomas E Klootwyk; Bruce A Levy; C Benjamin Ma; G Peter Maiers; Robert G Marx; Matthew J Matava; Gregory M Mathien; David R McAllister; Eric C McCarty; Robert G McCormack; Bruce S Miller; Carl W Nissen; Daniel F O'Neill; Brett D Owens; Richard D Parker; Mark L Purnell; Arun J Ramappa; Michael A Rauh; Arthur C Rettig; Jon K Sekiya; Kevin G Shea; Orrin H Sherman; James R Slauterbeck; Matthew V Smith; Jeffrey T Spang; Steven J Svoboda; Timothy N Taft; Joachim J Tenuta; Edwin M Tingstad; Armando F Vidal; Darius G Viskontas; Richard A White; James S Williams; Michelle L Wolcott; Brian R Wolf; James J York
Journal:  Am J Sports Med       Date:  2017-07-11       Impact factor: 6.202

7.  Clinical and arthroscopic outcomes of single-bundle anterior cruciate ligament reconstruction using autologous hamstrings augmented with ligament augmentation and reconstruction systems compared with four-strand hamstring tendon grafts alone.

Authors:  Hamood H G Zaid; Nan Chenwei; Hua Xu; Guo Yang; Xihai Li
Journal:  Int Orthop       Date:  2022-09-26       Impact factor: 3.479

Review 8.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

9.  Interference screws are more likely to perform better than cortical button and cross-pin fixation for hamstring autograft in ACL reconstruction: a Bayesian network meta-analysis.

Authors:  Lei Yan; Jiao Jiao Li; Yuanyuan Zhu; Haifeng Liu; Ruxing Liu; Bin Zhao; Bin Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-08-19       Impact factor: 4.342

10.  Computed Tomography Imaging of BioComposite Interference Screw After ACL Reconstruction With Bone-Patellar Tendon-Bone Graft.

Authors:  Brian Scrivens; Melissa A Kluczynski; Marc S Fineberg; Leslie J Bisson
Journal:  Orthop J Sports Med       Date:  2021-05-06
View more