Dopant titrating ion mobility spectrometry for trace exhaled nitric oxide detection.

Liying Peng1, Lei Hua, Enyou Li, Weiguo Wang, Qinghua Zhou, Xin Wang, Changsong Wang, Jinghua Li, Haiyang Li.   

Abstract

Ion mobility spectrometry (IMS) is a promising non-invasive tool for the analysis of exhaled gas and exhaled nitric oxide (NO), a biomarker for diagnosis of respiratory diseases. However, the high moisture in exhaled gas always brings about extra overlapping ion peaks and results in poor identification ability. In this paper, p-benzoquinone (PBQ) was introduced into IMS to eliminate the interference of overlapping ion peaks and realize the selective identification of NO. The overlapping ions caused by moisture were titrated by PBQ and then converted to hydrated PBQ anions (C6H4[Formula: see text](H2O)n). The NO concentration could be determined by quantifying gas phase hydrated nitrite anions (N[Formula: see text](H2O)n), product ions of NO. Under optimized conditions, a limit of detection (LOD) of about 1.4 ppbv and a linear range of 10-200 ppbv were obtained for NO even in 100% relative humidity (RH) purified air. Furthermore, this established method was applied to measure hourly the exhaled NO of eight healthy volunteers, and real-time monitoring the exhaled NO of an esophageal carcinoma patient during radical surgery. These results revealed the potential of the current dopant titrating IMS method in the measurement of exhaled NO for medical disease diagnosis.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25557839     DOI: 10.1088/1752-7155/9/1/016003

Source DB:  PubMed          Journal:  J Breath Res        ISSN: 1752-7155            Impact factor:   3.262


  3 in total

1.  A Novel Microwave-Induced Plasma Ionization Source for Ion Mobility Spectrometry.

Authors:  Jianxiong Dai; Zhongjun Zhao; Gaoling Liang; Yixiang Duan
Journal:  Sci Rep       Date:  2017-03-13       Impact factor: 4.379

2.  Online Measurement of Exhaled NO Concentration and Its Production Sites by Fast Non-equilibrium Dilution Ion Mobility Spectrometry.

Authors:  Liying Peng; Dandan Jiang; Zhenxin Wang; Jiwei Liu; Haiyang Li
Journal:  Sci Rep       Date:  2016-03-15       Impact factor: 4.379

Review 3.  Fractional exhaled nitric oxide-measuring devices: technology update.

Authors:  Mauro Maniscalco; Carolina Vitale; Alessandro Vatrella; Antonio Molino; Andrea Bianco; Gennaro Mazzarella
Journal:  Med Devices (Auckl)       Date:  2016-06-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.