Literature DB >> 25555967

Use of barbed suture in robot-assisted mitral valvuloplasty.

Go Watanabe1, Norihiko Ishikawa2.   

Abstract

Robot-assisted annuloplasty using a mitral band has a major issue: suturing is time consuming because knot tying is performed mechanically under endoscopic view. We suture the mitral band to the native valve by running sutures using the V-Loc barbed suture nonabsorbable wound closure device (Covidien, Mansfield, MA) with 3-0 monofilament. This technique allows rapid suturing of the band to the valve. Although conventional interrupted sutures leave multiple knots protruding on the band, using the V-Loc eliminates the need to tie surgical knots and leaves a clean surface, which may potentially reduce the risk of thrombogenesis. This method is highly useful for robotic mitral annuloplasty.
Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25555967     DOI: 10.1016/j.athoracsur.2014.07.054

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Barbed suture material technique for wound closure and concomitant tube placement in uniportal VATS for pneumothorax.

Authors:  Kyung Soo Kim
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

Review 2.  Minimally invasive cardiac surgery in Japan: history and current status.

Authors:  Kazuma Okamoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-07-17

3.  Robotic mitral valve repair in Japan and keyhole cardiac surgery in NewHeart Watanabe Institute.

Authors:  Norihiko Ishikawa; Go Watanabe
Journal:  Ann Cardiothorac Surg       Date:  2022-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.