Literature DB >> 25555225

Development of an automated ballast water treatment verification system utilizing fluorescein diacetate hydrolysis as a measure of treatment efficacy.

A C Akram1, S Noman1, R Moniri-Javid2, J P Gizicki1, E A Reed1, S B Singh1, A S Basu2, F Banno1, M Fujimoto1, J L Ram3.   

Abstract

Methods for verifying ballast water treatments in foreign vessels are needed to protect the Great Lakes from the discharge of live non-native organisms or pathogens. A prototype automated viability test system using fluorescein diacetate (FDA), a membrane permeable fluorogen, to differentiate live from dead bacteria and algae is described. The automated fluorescence intensity detection device (AFIDD) captures cultured algae or organisms in Detroit River water (simulated ballast water) on 0.2 μm filters, backwashes them from the filter into a cuvette with buffer and FDA for subsequent fluorescence intensity measurements, and washes the filters with sterile water for serial automated reuse. Preliminary manual versions of these procedures were also tested. Tests of various buffers determined N,N-Bis(2-hydroxyethyl)-2-aminoethanesulfonic acid, N,N-Bis(2-hydroxyethyl)taurine (BES) and 3-(N-morpholino)propanesulfonic acid (MOPS) at pH 7.0 to be the best buffers, causing the least spontaneous FDA breakdown without inhibiting enzymatic activity. Fluorescence in the presence of live organisms increased linearly over time, and the rate of increase was dependent on the sample concentration. Following simulated ballast water treatments with heat or chlorine, the fluorescence produced by Detroit River samples decreased to near control (sterile water) levels. Automated measurements of FDA hydrolysis with a reusable filter backwash system should be applicable to near real-time remote-controlled monitoring of live organisms in ballast water.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Automation; Ballast verification; Fluorescein diacetate; Viability testing

Mesh:

Substances:

Year:  2014        PMID: 25555225     DOI: 10.1016/j.watres.2014.12.009

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

1.  High efficiency inactivation of microalgae in ballast water by a new proposed dual-wave UV-photocatalysis system (UVA/UVC-TiO2).

Authors:  Zheng Lu; Kun Zhang; Xiaolei Liu; Yue Shi
Journal:  Environ Sci Pollut Res Int       Date:  2019-01-23       Impact factor: 4.223

Review 2.  Fluorescein Derivatives as Fluorescent Probes for pH Monitoring along Recent Biological Applications.

Authors:  Florent Le Guern; Vanessa Mussard; Anne Gaucher; Martin Rottman; Damien Prim
Journal:  Int J Mol Sci       Date:  2020-12-03       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.