Literature DB >> 25553960

Loosening detection of the femoral component of hip prostheses with extracorporeal shockwaves: a pilot study.

Johannes S Rieger1, Sebastian Jaeger1, Jan Philippe Kretzer1, Rüdiger Rupp2, Rudi G Bitsch3.   

Abstract

The diagnosis of aseptic loosening of hip implants is often challenging. A vibrational analysis of the bone-implant interface could be an alternative method to analyze the fixation of endoprostheses. We assessed an innovative and new approach for excitation by using extracorporeal shockwaves in this study. In three cadaver specimens total hip arthroplasty was performed bilaterally. Four different states of implant loosening were simulated. Three accelerometers were fixed at the medial condyle, the greater trochanter, and the crest of the ilium. The bone-implant compound was excited with highly standardized extracorporeal shock waves. Resonance spectra between 100 Hz and 5000 Hz were recorded. This technique permitted a good adaptation to varying soft tissue conditions. The main resonance frequency of the hip joints occurred at about 2000 Hz. The analysis of the measured spectra showed an interrelation between the state of loosening and the frequency values of the resonances. In case of a stem loosening, there were significant shifts of the resonance into the lower frequency area between 386 Hz and 847 Hz. With this novel technique the degree of stem loosening could be assessed in a soft tissue considering configuration. This study forms a first step for future establishment of a non-invasive, non-radiological and fast applicable diagnostic procedure for early detection of endoprostheses loosening before manifest presence of clinical signs.
Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Extracorporeal shockwaves; Hip arthroplasty; Loosening detection; Vibrational technique

Mesh:

Year:  2014        PMID: 25553960     DOI: 10.1016/j.medengphy.2014.11.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  2 in total

Review 1.  Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants.

Authors:  João Henrique Cachão; Marco P Soares Dos Santos; Rodrigo Bernardo; António Ramos; Rainer Bader; Jorge A F Ferreira; António Torres Marques; José A O Simões
Journal:  Sensors (Basel)       Date:  2019-12-23       Impact factor: 3.576

2.  Multiscale Sensing of Bone-Implant Loosening for Multifunctional Smart Bone Implants: Using Capacitive Technologies for Precision Controllability.

Authors:  Inês Peres; Pedro Rolo; Jorge A F Ferreira; Susana C Pinto; Paula A A P Marques; António Ramos; Marco P Soares Dos Santos
Journal:  Sensors (Basel)       Date:  2022-03-25       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.