Literature DB >> 25549774

Validity and Reliability of Gait and Postural Control Analysis Using the Tri-axial Accelerometer of the iPod Touch.

Nienke M Kosse1, Simone Caljouw, Danique Vervoort, Nicolas Vuillerme, Claudine J C Lamoth.   

Abstract

Accelerometer-based assessments can identify elderly with an increased fall risk and monitor interventions. Smart devices, like the iPod Touch, with built-in accelerometers are promising for clinical gait and posture assessments due to easy use and cost-effectiveness. The aim of the present study was to establish the validity and reliability of the iPod Touch for gait and posture assessment. Sixty healthy participants (aged 18-75 years) were measured with an iPod Touch and stand-alone accelerometer while they walked under single- and dual-task conditions, and while standing in parallel and semi-tandem stance with eyes open, eyes closed and when performing a dual task. Cross-correlation values (CCV) showed high correspondence of anterior-posterior and medio-lateral signal patterns (CCV's ≥ 0.88). Validity of gait parameters (foot contacts, index of harmonicity, and amplitude variability) and standing posture parameters [root mean square of accelerations, median power frequency (MPF) and sway area] as indicated by intra-class correlation (ICC) was high (ICC = 0.85-0.99) and test-retest reliability was good (ICC = 0.81-0.97), except for MPF (ICC = 0.59-0.87). Overall, the iPod Touch obtained valid and reliable measures of gait and postural control in healthy adults of all ages under different conditions. Additionally, smart devices have the potential to be used for clinical gait and posture assessments.

Entities:  

Mesh:

Year:  2014        PMID: 25549774     DOI: 10.1007/s10439-014-1232-0

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  22 in total

1.  Reliability, Validity and Utility of Inertial Sensor Systems for Postural Control Assessment in Sport Science and Medicine Applications: A Systematic Review.

Authors:  William Johnston; Martin O'Reilly; Rob Argent; Brian Caulfield
Journal:  Sports Med       Date:  2019-05       Impact factor: 11.136

2.  Anticholinergic and Sedative Medications and Dynamic Gait Parameters in Older Patients.

Authors:  Hans Wouters; Jos P Van Campen; Marloes J Kuitert; Lisette Kikkert; Sarah N Hilmer; Katja Taxis; Helene G Van der Meer; Claudine J C Lamoth
Journal:  Drugs Aging       Date:  2021-12-02       Impact factor: 3.923

3.  Multivariate Analyses and Classification of Inertial Sensor Data to Identify Aging Effects on the Timed-Up-and-Go Test.

Authors:  Danique Vervoort; Nicolas Vuillerme; Nienke Kosse; Tibor Hortobágyi; Claudine J C Lamoth
Journal:  PLoS One       Date:  2016-06-06       Impact factor: 3.240

4.  Reliability of smartphone-based gait measurements for quantification of physical activity/inactivity levels.

Authors:  Takeshi Ebara; Ryohei Azuma; Naoto Shoji; Tsuyoshi Matsukawa; Yasuyuki Yamada; Tomohiro Akiyama; Takahiro Kurihara; Shota Yamada
Journal:  J Occup Health       Date:  2017-08-24       Impact factor: 2.708

5.  Gait characteristics and their discriminative power in geriatric patients with and without cognitive impairment.

Authors:  Lisette H J Kikkert; Nicolas Vuillerme; Jos P van Campen; Bregje A Appels; Tibor Hortobágyi; Claudine J C Lamoth
Journal:  J Neuroeng Rehabil       Date:  2017-08-15       Impact factor: 4.262

6.  Internal Consistency of Sway Measures via Embedded Head-Mounted Accelerometers: Implications for Neuromotor Investigations.

Authors:  Andrew P Lapointe; Jessica N Ritchie; Rachel V Vitali; Joel S Burma; Ateyeh Soroush; Ibukunoluwa Oni; Jeff F Dunn
Journal:  Sensors (Basel)       Date:  2021-06-30       Impact factor: 3.576

7.  Evaluation of Concurrent Validity between a Smartphone Self-Test Prototype and Clinical Instruments for Balance and Leg Strength.

Authors:  Linda Mansson; Pernilla Bäckman; Fredrik Öhberg; Jonas Sandlund; Jonas Selling; Marlene Sandlund
Journal:  Sensors (Basel)       Date:  2021-03-04       Impact factor: 3.576

8.  Performance Evaluation of Smartphone Inertial Sensors Measurement for Range of Motion.

Authors:  Quentin Mourcou; Anthony Fleury; Céline Franco; Frédéric Klopcic; Nicolas Vuillerme
Journal:  Sensors (Basel)       Date:  2015-09-15       Impact factor: 3.576

9.  Clinical assessment tools identify functional deficits in fragility fracture patients.

Authors:  Tyler D Ames; Corinne E Wee; Khoi M Le; Tiffany L Wang; Julie Y Bishop; Laura S Phieffer; Carmen E Quatman
Journal:  Clin Interv Aging       Date:  2016-05-05       Impact factor: 4.458

10.  The Evaluation of Physical Stillness with Wearable Chest and Arm Accelerometer during Chan Ding Practice.

Authors:  Kang-Ming Chang; Yu-Teng Chun; Sih-Huei Chen; Luo Lu; Hsiao-Ting Jannis Su; Hung-Meng Liang; Jayasree Santhosh; Congo Tak-Shing Ching; Shing-Hong Liu
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

View more