Literature DB >> 25545281

Transcatheter aortic-valve implantation with one single minimal contrast media injection.

Mattia Arrigo1, Francesco Maisano2, Sabine Haueis1, Ronald K Binder1, Maurizio Taramasso2, Fabian Nietlispach1.   

Abstract

OBJECTIVES: Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI).
BACKGROUND: Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN.
METHODS: Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics.
RESULTS: Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline.
CONCLUSIONS: Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  TAVI; acute kidney injury; contrast media; kidney disease; minimalist approach

Mesh:

Substances:

Year:  2015        PMID: 25545281     DOI: 10.1002/ccd.25799

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Efficacy and Safety of Emergent Transcatheter Aortic Valve Implantation in Patients with Acute Decompensated Aortic Stenosis: Systematic Review and Meta-Analysis.

Authors:  Ruochen Shao; Junli Li; Tianyi Qu; Xiaoying Fu; Yanbiao Liao; Mao Chen
Journal:  J Interv Cardiol       Date:  2021-12-24       Impact factor: 2.279

2.  Volume of contrast to creatinine clearance ratio predicts early mortality and AKI after TAVI.

Authors:  Gabriele Venturi; Roberto Scarsini; Michele Pighi; Rafail A Kotronias; Anna Piccoli; Mattia Lunardi; Paolo Del Sole; Andrea Mainardi; Alessia Gambaro; Domenico Tavella; Giovanni L De Maria; Rajesh Kharbanda; Gabriele Pesarini; Adrian Banning; Flavio Ribichini
Journal:  Catheter Cardiovasc Interv       Date:  2022-03-21       Impact factor: 2.585

  2 in total