Literature DB >> 25544010

A sensitive method for digoxin determination using formate-adduct ion based on the effect of ionization enhancement in liquid chromatograph-mass spectrometer.

Xia Li1, Yu Wang1, Qingyuan Zhou1, Yunqiu Yu2, Lihong Chen3, Jie Zheng3.   

Abstract

A sensitive and rapid method based on formate-adduct ion detection was developed and fully validated for digoxin determination in rat plasma. For LC/MS/MS detection with formate-adducts as precursor ions, transitions of m/z 825.5→779.9 for digoxin and m/z 809.5→763.4 for the internal standard (digitoxin) were monitored in negative mode. To investigate the impact of formic acid on the mass response and method sensitivity, a formic acid concentration range of 0-0.1% (0, 0.0005%, 0.002%, 0.01%, 0.1%, v/v) was evaluated. A concentration of 0.002% gave the highest sensitivity, which was 16- to 18-fold higher than deprotonated ions, and was designated as the contribution giving the strongest ionization enhancement and adduction. A number of parameters were then varied in order to optimize the method, and a limit of quantitation (LOQ) at 0.2 ng/mL was reached with an injection volume of 5 μL, a total run time of 3 min, and 0.1 mL of rat plasma. A calibration curve was plotted over the range 0.2-50 ng/mL (R(2)=0.9998), and the method was successfully applied to study pharmacokinetics in rat following a single oral administration of digoxin (0.05 mg/kg). Four additional steroid saponins (digitoxin, deslanoside, ginsenoside Rg1 and Rb1) were investigated to assess the impact of formic acid on the mass response of steroid saponins. Compounds with a conjugated lactonic ring in their structures such as digoxin, digitoxin and deslanoside tended to form stable formate-adduct ions more easily. The LC/MS/MS method developed here is therefore well suited for the quantification of steroid saponins that are difficult to deprotonate using other MS approaches.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Digoxin; Formate-adduct; LC/MS/MS; Rat plasma; Sensitivity

Mesh:

Substances:

Year:  2014        PMID: 25544010     DOI: 10.1016/j.jchromb.2014.11.023

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  2 in total

1.  Development of a new ultra-high-performance liquid chromatography-tandem mass spectrometry method for the determination of digoxin and digitoxin in plasma: Comparison with a clinical immunoassay.

Authors:  Marco Ballotari; Francesco Taus; Giulia Tolle; Elisa Danese; Romolo M Dorizzi; Franco Tagliaro; Rossella Gottardo
Journal:  Electrophoresis       Date:  2022-02-17       Impact factor: 3.595

2.  Development of Indirect Competitive Enzyme-Linked Immunosorbent Assay and Lateral-Flow Immunochromatographic Strip for the Detection of Digoxin in Human Blood.

Authors:  Fanqian Ling; Liqiang Liu; Hua Kuang; Gang Cui; Chuanlai Xu
Journal:  ACS Omega       Date:  2020-01-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.