Literature DB >> 25543132

EURADOS intercomparison on emergency radiobioassay.

Chunsheng Li1, Paolo Battisti2, Philippe Berard3, Alain Cazoulat4, Antonio Cuellar5, Rodolfo Cruz-Suarez5, Xiongxin Dai6, Isabella Giardina2, Derek Hammond7, Carolina Hernandez8, Stephen Kiser9, Raymond Ko9, Sheila Kramer-Tremblay6, Yannick Lecompte4, Eva Navarro10, Cristina Navas10, Baki Sadi9, Inmaculada Sierra8, Freddy Verrezen11, Maria A Lopez8.   

Abstract

Nine laboratories participated in an intercomparison exercise organised by the European Radiation Dosimetry Group (EURADOS) for emergency radiobioassay involving four high-risk radionuclides ((239)Pu, (241)Am, (90)Sr and (226)Ra). Diverse methods of analysis were used by the participating laboratories for the in vitro determination of each of the four radionuclides in urine samples. Almost all the methods used are sensitive enough to meet the requirements for emergency radiobioassay derived for this project in reference to the Clinical Decision Guide introduced by the NCRP. Results from most of the methods meet the requirements of ISO 28218 on accuracy in terms of relative bias and relative precision. However, some technical gaps have been identified. For example, some laboratories do not have the ability to assay samples containing (226)Ra, and sample turnaround time would be expected to be much shorter than that reported by many laboratories, as timely results for internal contamination and early decisions on medical intervention are highly desired. Participating laboratories are expected to learn from each other on the methods used to improve the interoperability among these laboratories.
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25543132     DOI: 10.1093/rpd/ncu366

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  1 in total

1.  GHSI EMERGENCY RADIONUCLIDE BIOASSAY LABORATORY NETWORK: SUMMARY OF A RECENT EXERCISE.

Authors:  Chunsheng Li; Armin Ansari; Christine Bartizel; Paolo Battisti; Didier Franck; Udo Gerstmann; Isabella Giardina; Claude Guichet; Derek Hammond; Martina Hartmann; Robert L Jones; Eunjoo Kim; Raymond Ko; Ryan Morhard; Deborah Quayle; Baki Sadi; David Saunders; Francois Paquet
Journal:  Radiat Prot Dosimetry       Date:  2015-09-23       Impact factor: 0.972

  1 in total