Literature DB >> 25540835

Combined BAC and MIEX pre-treatment of secondary wastewater effluent to reduce fouling of nanofiltration membranes.

Ashok Aryal1, Arumugam Sathasivan2, Anna Heitz3, Gang Zheng4, Hamid Nikraz3, Maneesha P Ginige5.   

Abstract

Biological activated carbon (BAC) and magnetic ion exchange resin (MIEX) were used to pre-treat secondary wastewater effluent (SWWE) and assessed for their capacity to reduce fouling of a nanofiltration membrane. BAC pre-treated water facilitated a lower but a steady flux while MIEX treated water resulted in a higher but a rapidly declining flux. Their combined use increased average flux from 58 to 89%. MIEX combined with BAC, in that order, was superior in reducing membrane fouling. Measurement of average Stokes radius (m) and apparent molecular weight distribution of dissolved organic matter (DOM), by nuclear magnetic resonance (NMR) and liquid chromatography organic carbon detection (LC-OCD), respectively, revealed that the microbial activity of BAC changed the nature of organic matter, probably by increasing the size of DOM molecules. BAC generally decreased the lower apparent molecular weight (LMW) fraction of dissolved organic carbon (DOC). Hence, the removal of LMW DOC and an increase of average Stokes radius (m) of DOM appeared to be important in facilitating a longer steady flux. Specifically, the combined MIEX/BAC pre-treatments appeared to target and reduce the foulants in SWWE that are largely responsible for the reduction of flux in nanofiltration membranes.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biologically activated carbon; MIEX; Membrane fouling; Wastewater treatment

Mesh:

Substances:

Year:  2014        PMID: 25540835     DOI: 10.1016/j.watres.2014.12.003

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  Evaluation of the treatment performance and microbial communities of a combined constructed wetland used to treat industrial park wastewater.

Authors:  Ming Xu; Weijing Liu; Chao Li; Chun Xiao; Lili Ding; Ke Xu; Jinju Geng; Hongqiang Ren
Journal:  Environ Sci Pollut Res Int       Date:  2016-02-23       Impact factor: 4.223

2.  Combining Coagulation/MIEX with Biological Activated Carbon Treatment to Control Organic Fouling in the Microfiltration of Secondary Effluent.

Authors:  Biplob Kumar Pramanik; Felicity A Roddick; Linhua Fan
Journal:  Membranes (Basel)       Date:  2016-07-30

3.  Pilot Study on the Combination of Different Pre-Treatments with Nanofiltration for Efficiently Restraining Membrane Fouling While Providing High-Quality Drinking Water.

Authors:  Yan Chen; Huiping Li; Weihai Pang; Baiqin Zhou; Tian Li; Jian Zhang; Bingzhi Dong
Journal:  Membranes (Basel)       Date:  2021-05-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.