Literature DB >> 25539988

Orthodontic miniscrews: an experimental campaign on primary stability and bone properties.

Marco Migliorati1, Sara Drago2, Irene Schiavetti3, Francesco Olivero2, Fabrizio Barberis4, Alberto Lagazzo4, Marco Capurro4, Armando Silvestrini-Biavati2, Stefano Benedicenti5.   

Abstract

OBJECTIVE: To evaluate the primary stability of different shaped miniscrews through the acquisition of data regarding maximum insertion torque, pullout force, and a radiodiagnosic evaluation of bone characteristics.
MATERIALS AND METHODS: Sixty fresh porcine bone samples were scanned by computed tomography (CT) and cone-beam computed tomography (CBCT). By means of a dedicated software, CT and CBCT images were analysed to measure the insertion-site cortical thickness, cortical density, and marrow bone density. Sixty miniscrews of 12 different types were implanted with no predrilling pilot hole in the bone samples. Every device was tightened by means of a digital torque screwdriver and torque data were collected. Subsequently, pullout tests were performed. Spearman and Pearson correlations were employed to compare any relationship between continuous variables.
RESULTS: Different types of miniscrews did not show statistically significant differences in their torque value (P = 0.595), instead a significant difference was revealed by considering their load measures (P = 0.039). Cortical bone thickness resulted strongly correlated both with value of load (P < 0.001), and modestly with torque measures (P = 0.004). A strong positive correlation was found between CT and CBCT both for cortical density (P < 0.001) and marrow bone density (P < 0.001).
CONCLUSION: Bone characteristics play the major role in miniscrews primary stability.
© The Author 2014. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

Mesh:

Year:  2014        PMID: 25539988     DOI: 10.1093/ejo/cju081

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  5 in total

1.  Analysis of biological and structural factors implicated in the clinical success of orthodontic miniscrews at posterior maxillary interradicular sites.

Authors:  M Palone; A Darsiè; G B Maino; G Siciliani; G A Spedicato; L Lombardo
Journal:  Clin Oral Investig       Date:  2021-11-27       Impact factor: 3.573

2.  Mechanical stability of orthodontic miniscrew depends on a thread shape.

Authors:  Keiichiro Watanabe; Bobby Mitchell; Takuma Sakamaki; Yuzo Hirai; Do-Gyoon Kim; Toru Deguchi; Masakazu Suzuki; Kanji Ueda; Eiji Tanaka
Journal:  J Dent Sci       Date:  2021-12-11       Impact factor: 3.719

3.  Three dimensional movement analysis of maxillary impacted canine using TADs: a pilot study.

Authors:  Marco Migliorati; Lucia Cevidanes; Giordana Sinfonico; Sara Drago; Domenico Dalessandri; Gaetano Isola; Armando Silvestrini Biavati
Journal:  Head Face Med       Date:  2021-01-15       Impact factor: 2.151

4.  Correlation between cortical bone thickness at mini-implant insertion sites and age of patient.

Authors:  Anna Carolina Teixeira Centeno; Caroline Kolling Fensterseifer; Vitória de Oliveira Chami; Eduardo Silveira Ferreira; Mariana Marquezan; Vilmar Antônio Ferrazzo
Journal:  Dental Press J Orthod       Date:  2022-02-28

5.  Bone quality affects stability of orthodontic miniscrews.

Authors:  Wan-Ping Yu; Ming-Tzu Tsai; Jian-Hong Yu; Heng-Li Huang; Jui-Ting Hsu
Journal:  Sci Rep       Date:  2022-02-18       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.