Literature DB >> 25539940

Instantaneous quantification of skeletal muscle activation, power production, and fatigue during cycle ergometry.

A C Coelho1, D T Cannon2, R Cao2, J Porszasz2, R Casaburi2, M M Knorst3, H B Rossiter4.   

Abstract

A rapid switch from hyperbolic to isokinetic cycling allows the velocity-specific decline in maximal power to be measured, i.e., fatigue. We reasoned that, should the baseline relationship between isokinetic power (Piso) and electromyography (EMG) be reproducible, then contributions to fatigue may be isolated from 1) the decline in muscle activation (muscle activation fatigue); and 2) the decline in Piso at a given activation (muscle fatigue). We hypothesized that the EMG-Piso relationship is linear, velocity dependent, and reliable for instantaneous fatigue assessment at intolerance during and following whole body exercise. Healthy participants (n = 13) completed short (5 s) variable-effort isokinetic bouts at 50, 70, and 100 rpm to characterize baseline EMG-Piso. Repeated ramp incremental exercise tests were terminated with maximal isokinetic cycling (5 s) at 70 rpm. Individual baseline EMG-Piso relationships were linear (r(2) = 0.95 ± 0.04) and velocity dependent (analysis of covariance). Piso at intolerance (two legs, 335 ± 88 W) was ∼45% less than baseline [630 ± 156 W, confidence interval of the difference (CIDifference) 211, 380 W, P < 0.05]. Following intolerance, Piso recovered rapidly (F = 44.1; P < 0.05; η(2) = 0.79): power was reduced (P < 0.05) vs. baseline only at 0-min (CIDifference 80, 201 W) and 1-min recovery (CIDifference 13, 80 W). Activation fatigue and muscle fatigue (one leg) were 97 ± 55 and 60 ± 50 W, respectively. Mean bias ± limits of agreement for reproducibility were as follows: baseline Piso 1 ± 30 W; Piso at 0-min recovery 3 ± 35 W; and EMG at Piso 3 ± 14%. EMG power is linear, velocity dependent, and reproducible. Deviation from this relationship at the limit of tolerance can quantify the "activation" and "muscle" related components of fatigue during cycling.
Copyright © 2015 the American Physiological Society.

Entities:  

Keywords:  electromyography; exercise testing; isokinetic; muscle fatigue; performance fatigue

Mesh:

Year:  2014        PMID: 25539940     DOI: 10.1152/japplphysiol.00948.2014

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  11 in total

1.  Oral L-menthol reduces thermal sensation, increases work-rate and extends time to exhaustion, in the heat at a fixed rating of perceived exertion.

Authors:  T R Flood; M Waldron; O Jeffries
Journal:  Eur J Appl Physiol       Date:  2017-05-15       Impact factor: 3.078

2.  Shorter constant work rate cycling tests as proxies for longer tests in highly trained cyclists.

Authors:  Chantelle du Plessis; Mark Andrews; Lachlan J G Mitchell; Jodie Cochrane Wilkie; Trish King; Anthony J Blazevich
Journal:  PLoS One       Date:  2022-05-23       Impact factor: 3.752

Review 3.  Critical Power: An Important Fatigue Threshold in Exercise Physiology.

Authors:  David C Poole; Mark Burnley; Anni Vanhatalo; Harry B Rossiter; Andrew M Jones
Journal:  Med Sci Sports Exerc       Date:  2016-11       Impact factor: 5.411

4.  Power reserve following ramp-incremental cycling to exhaustion: implications for muscle fatigue and function.

Authors:  Michael D Hodgson; Daniel A Keir; David B Copithorne; Charles L Rice; John M Kowalchuk
Journal:  J Appl Physiol (1985)       Date:  2018-04-26

5.  Increased PIO2 at Exhaustion in Hypoxia Enhances Muscle Activation and Swiftly Relieves Fatigue: A Placebo or a PIO2 Dependent Effect?

Authors:  Rafael Torres-Peralta; José Losa-Reyna; David Morales-Alamo; Miriam González-Izal; Ismael Pérez-Suárez; Jesús G Ponce-González; Mikel Izquierdo; José A L Calbet
Journal:  Front Physiol       Date:  2016-08-17       Impact factor: 4.566

Review 6.  A systematic review of surface electromyography analyses of the bench press movement task.

Authors:  Petr Stastny; Artur Gołaś; Dusan Blazek; Adam Maszczyk; Michał Wilk; Przemysław Pietraszewski; Miroslav Petr; Petr Uhlir; Adam Zając
Journal:  PLoS One       Date:  2017-02-07       Impact factor: 3.240

7.  Changes in VO2 Kinetics After Elevated Baseline Do Not Necessarily Reflect Alterations in Muscle Force Production in Both Sexes.

Authors:  Paulo Cesar do Nascimento Salvador; Lisa Schäfer; Bruno Grassi; Luiz Guilherme Antonacci Guglielmo; Benedito Sérgio Denadai
Journal:  Front Physiol       Date:  2019-04-25       Impact factor: 4.566

8.  Toward the Personalization of Biceps Fatigue Detection Model for Gym Activity: An Approach to Utilize Wearables' Data from the Crowd.

Authors:  Mohamed Elshafei; Diego Elias Costa; Emad Shihab
Journal:  Sensors (Basel)       Date:  2022-02-14       Impact factor: 3.576

9.  Task Failure during Exercise to Exhaustion in Normoxia and Hypoxia Is Due to Reduced Muscle Activation Caused by Central Mechanisms While Muscle Metaboreflex Does Not Limit Performance.

Authors:  Rafael Torres-Peralta; David Morales-Alamo; Miriam González-Izal; José Losa-Reyna; Ismael Pérez-Suárez; Mikel Izquierdo; José A L Calbet
Journal:  Front Physiol       Date:  2016-01-11       Impact factor: 4.566

10.  Feasibility of Muscle Activity Assessment With Surface Electromyography During Bed Cycling Exercise In Intensive Care Unit Patients.

Authors:  Juultje Sommers; Michelle Van Den Boorn; Raoul H H Engelbert; Frans Nollet; Marike Van Der Schaaf; Janneke Horn
Journal:  Muscle Nerve       Date:  2018-10-02       Impact factor: 3.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.