Literature DB >> 25536668

Analytical evaluation of Diazyme procalcitonin (PCT) latex-enhanced immunoturbidimetric assay on Beckman Coulter AU5800.

Mariella Dipalo, Ruggero Buonocore, Cecilia Gnocchi, Alessandra Picanza, Rosalia Aloe, Giuseppe Lippi.   

Abstract

BACKGROUND: This study was aimed to evaluate the analytical performance of the novel Diazyme procalcitonin (PCT) immunoturbidimetric assay on Beckman Coulter AU5800.
METHODS: Diazyme PCT is a latex-enhanced immunoturbidimetric assay, developed for use on laboratory instrumentations with capability of reading absorbance at 600 nm. This analytical evaluation included the assessment of limit of blank (LOB), limit of detection (LOD), functional sensitivity, imprecision, linearity, carryover, and method comparison between Diazyme PCT and Kryptor PCT on 129 routine serum inpatient samples.
RESULTS: The LOB, LOD, and functional sensitivity of Diazyme PCT were 0.16, 0.26, and 0.28 ng/mL, respectively. The intra- and inter-assay imprecision of Diazyme PCT was between 2.9% and 7.8%. The linearity was excellent in the range of PCT values between 0.16 and 56 ng/mL, and the carryover was negligible (0.02%). A highly significant agreement was found between Kryptor PCT and Diazyme PCT in a range of concentrations between 0.16 and 111 ng/mL (Diazyme PCT=1.10×Kryptor PCT-0.89; r=0.960; p<0.001). The mean bias was 0.48 ng/mL (95% CI, -0.58 to 1.54 ng/mL). The strength of agreement between Kryptor PCT and Diazyme PCT was between 85% and 96% at 0.50, 2.0, and 10 ng/mL cutoffs.
CONCLUSIONS: Diazyme PCT appears to be a reliable assay for diagnosis and management of critical care patients susceptible to severe bacterial infections.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25536668     DOI: 10.1515/cclm-2014-1118

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  4 in total

1.  Multicenter comparison of automated procalcitonin immunoassays.

Authors:  Mariella Dipalo; Lorena Guido; Gianmatteo Micca; Salvatore Pittalis; Massimo Locatelli; Andrea Motta; Vincenza Bianchi; Tiziana Callegari; Rosalia Aloe; Giorgio Da Rin; Giuseppe Lippi
Journal:  Pract Lab Med       Date:  2015-07-17

2.  Analytical performances of a novel point-of-care procalcitonin assay.

Authors:  Anne Marie Dupuy; Anne Sophie Bargnoux; Aneta Andreeva; Charlie Zins; Nils Kuster; Stéphanie Badiou; Jean Paul Cristol
Journal:  Pract Lab Med       Date:  2019-10-26

3.  Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay.

Authors:  Orazio Ruzzenente; Gian Luca Salvagno; Matteo Gelati; Giuseppe Lippi
Journal:  Pract Lab Med       Date:  2016-07-16

4.  Increased levels of glycosylated hemoglobin, microalbuminuria and serum cystatin C predict adverse outcomes in high-risk pregnancies with gestational diabetes mellitus.

Authors:  Hongmei Jin
Journal:  Exp Ther Med       Date:  2019-12-17       Impact factor: 2.447

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.