Literature DB >> 25535809

Cone-Beam Computed Tomography Evaluation of Horizontal and Vertical Dimensional Changes in Buccal Peri-Implant Alveolar Bone and Soft Tissue: A 1-Year Prospective Clinical Study.

Akihiro Kaminaka1, Tamaki Nakano1, Shinji Ono1, Tokinori Kato1, Hirofumi Yatani1.   

Abstract

PURPOSE: This study evaluated changes in the horizontal and vertical dimensions of the buccal alveolar bone and soft tissue over a 1-year period following implant prosthesis.
MATERIALS AND METHODS: Thirty-three participants with no history of guided bone regeneration or soft tissue augmentation underwent dental implant placement with different types of connections. The dimensions of the buccal alveolar bone and soft tissue were evaluated immediately and at 1 year after prosthesis from reconstructions of cross-sectional cone-beam computed tomography images.
RESULTS: The vertical and horizontal loss of buccal bone and soft tissue around implants with conical connections were lower than around those with external or internal connections. Statistically significant negative correlations were observed between initial horizontal bone thickness and changes in vertical bone and soft tissue height (p < .05), and between initial horizontal soft tissue thickness and the change in vertical soft tissue height (p < .05).
CONCLUSION: Implants with a conical connection preserve peri-implant alveolar bone and soft tissue more effectively than other connection types. Furthermore, the initial buccal alveolar bone and soft tissue thickness around the implant platform may influence their vertical dimensional changes at 1 year after implant prosthesis.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  abutment design; clinical study; cone beam CT; implants; prei-implant tissue; prospective

Mesh:

Year:  2014        PMID: 25535809     DOI: 10.1111/cid.12286

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  6 in total

1.  Correlation between gingival phenotype in the aesthetic zone and craniofacial profile-a CBCT-based study.

Authors:  Sa Cha; Sueng Min Lee; Chengxiaoxue Zhang; Zhen Tan; Qing Zhao
Journal:  Clin Oral Investig       Date:  2020-07-09       Impact factor: 3.573

2.  Fracture Resistance of Zirconia Abutments with or without a Titanium Base: An In Vitro Study for Tapered Conical Connection Implants.

Authors:  Shota Watanabe; Tamaki Nakano; Shinji Ono; Yasufumi Yamanishi; Takashi Matsuoka; Shoichi Ishigaki
Journal:  Materials (Basel)       Date:  2022-01-05       Impact factor: 3.623

3.  Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis.

Authors:  Takashi Matsuoka; Tamaki Nakano; Satoshi Yamaguchi; Shinji Ono; Shota Watanabe; Takumi Sato; Hirofumi Yatani
Journal:  Materials (Basel)       Date:  2021-05-06       Impact factor: 3.623

4.  CBCT analysis of the tissue thickness at immediate implant placement with contour augmentation in the maxillary anterior zone: a 1-year prospective clinical study.

Authors:  Yuya Fujita; Tamaki Nakano; Shinji Ono; Takuya Shimomoto; Keiichiro Mizuno; Hirofumi Yatani; Shoichi Ishigaki
Journal:  Int J Implant Dent       Date:  2021-07-06

Review 5.  Accuracy and precision of cone beam computed tomography in periodontal defects measurement (systematic review).

Authors:  Enas Anter; Mohammed Khalifa Zayet; Sahar Hosny El-Dessouky
Journal:  J Indian Soc Periodontol       Date:  2016 May-Jun

Review 6.  Buccal Bone Thickness in Anterior and Posterior Teeth-A Systematic Review.

Authors:  Diana Heimes; Eik Schiegnitz; Robert Kuchen; Peer W Kämmerer; Bilal Al-Nawas
Journal:  Healthcare (Basel)       Date:  2021-11-30
  6 in total