Literature DB >> 25534787

Development of a high-throughput UHPLC-MS/MS (SRM) method for the quantitation of endogenous glucagon from human plasma.

James W Howard1, Richard G Kay, Tricia Tan, James Minnion, Mohammad Ghatei, Steve Bloom, Colin S Creaser.   

Abstract

BACKGROUND: Published LC-MS/MS methods are not sensitive enough to quantify endogenous levels of glucagon.
RESULTS: An ultra high performance liquid chromatography-MS/MS (SRM) method for the quantitation of endogenous levels glucagon was successfully developed and qualified. A novel 2D extraction procedure was used to reduce matrix suppression, background noise and interferences. Glucagon levels in samples from healthy volunteers were found to agree with radioimmunoassay (RIA) derived literature values. Bland-Altman analysis showed a concentration-dependent positive bias of the LC/MS-MS assay versus an RIA. Both assays produced similar pharmacokinetic profiles, both of which were feasible considering the nature of the study.
CONCLUSION: Our method is the first peer reviewed LC-MS/MS method for the quantitation of endogenous levels of glucagon, and offers a viable alternative to RIA-based approaches.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25534787     DOI: 10.4155/bio.14.226

Source DB:  PubMed          Journal:  Bioanalysis        ISSN: 1757-6180            Impact factor:   2.681


  4 in total

1.  Peptidomic analysis of endogenous plasma peptides from patients with pancreatic neuroendocrine tumours.

Authors:  Richard G Kay; Benjamin G Challis; Ruth T Casey; Geoffrey P Roberts; Claire L Meek; Frank Reimann; Fiona M Gribble
Journal:  Rapid Commun Mass Spectrom       Date:  2018-08-30       Impact factor: 2.419

2.  Rapid liquid chromatography-mass spectrometry quantitation of glucose-regulating hormones from human islets of Langerhans.

Authors:  Matthew J Donohue; Robert T Filla; Daniel J Steyer; Wesley J Eaton; Michael G Roper
Journal:  J Chromatogr A       Date:  2020-12-15       Impact factor: 4.759

3.  Inability of Some Commercial Assays to Measure Suppression of Glucagon Secretion.

Authors:  Nicolai J Wewer Albrechtsen; Simon Veedfald; Astrid Plamboeck; Carolyn F Deacon; Bolette Hartmann; Filip K Knop; Tina Vilsboll; Jens J Holst
Journal:  J Diabetes Res       Date:  2015-12-29       Impact factor: 4.011

4.  Liquid chromatography/mass spectrometry based detection and semi-quantitative analysis of INSL5 in human and murine tissues.

Authors:  R G Kay; S Galvin; P Larraufie; F Reimann; F M Gribble
Journal:  Rapid Commun Mass Spectrom       Date:  2017-12-15       Impact factor: 2.419

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.