Literature DB >> 25532165

Wavelet-based regularization for robust microwave imaging in medical applications.

Rosa Scapaticci1, Panagiotis Kosmas2, Lorenzo Crocco3.   

Abstract

Microwave imaging (MWI) is an emerging tool for medical diagnostics, potentially offering unique advantages such as the capability of providing quantitative images of the inspected tissues. This involves, however, solving a challenging nonlinear and ill-posed electromagnetic inverse scattering problem. This paper presents a robust method for quantitative MWI in medical applications where very little, if any, a priori information on the imaging scenario is available. This is accomplished by employing a distorted Born iterative method and a regularization by projection technique, which reconstructs the tissue parameters using a wavelet basis expansion to represent the unknown contrast. This approach is suited for any microwave medical imaging application where the requirement for increased resolution dictates the use of higher frequency data and, consequently, a robust regularization strategy. To demonstrate the robustness of the proposed approach, this paper presents reconstructions of highly heterogeneous anatomically realistic numerical breast phantoms in a canonical 2-D configuration.

Entities:  

Mesh:

Year:  2015        PMID: 25532165     DOI: 10.1109/TBME.2014.2381270

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  8 in total

1.  Two-step inversion with a logarithmic transformation for microwave breast imaging.

Authors:  Paul M Meaney; Shireen D Geimer; Keith D Paulsen
Journal:  Med Phys       Date:  2017-07-17       Impact factor: 4.071

2.  Detectability of Breast Tumor by a Hand-held Impulse-Radar Detector: Performance Evaluation and Pilot Clinical Study.

Authors:  Hang Song; Shinsuke Sasada; Takayuki Kadoya; Morihito Okada; Koji Arihiro; Xia Xiao; Takamaro Kikkawa
Journal:  Sci Rep       Date:  2017-11-27       Impact factor: 4.379

3.  Microwave Bone Imaging: A Preliminary Investigation on Numerical Bone Phantoms for Bone Health Monitoring.

Authors:  Bilal Amin; Atif Shahzad; Martin O'Halloran; Muhammad Adnan Elahi
Journal:  Sensors (Basel)       Date:  2020-11-05       Impact factor: 3.576

4.  Expansion of the Nodal-Adjoint Method for Simple and Efficient Computation of the 2D Tomographic Imaging Jacobian Matrix.

Authors:  Samar Hosseinzadegan; Andreas Fhager; Mikael Persson; Shireen Geimer; Paul Meaney
Journal:  Sensors (Basel)       Date:  2021-01-22       Impact factor: 3.576

5.  A Discrete Dipole Approximation Solver Based on the COCG-FFT Algorithm and Its Application to Microwave Breast Imaging.

Authors:  Samar Hosseinzadegan; Andreas Fhager; Mikael Persson; Paul Meaney
Journal:  Int J Antennas Propag       Date:  2019-07-17       Impact factor: 1.174

6.  Hardware design and implementation of a wavelet de-noising procedure for medical signal preprocessing.

Authors:  Szi-Wen Chen; Yuan-Ho Chen
Journal:  Sensors (Basel)       Date:  2015-10-16       Impact factor: 3.576

7.  Design and Experimental Validation of a Multiple-Frequency Microwave Tomography System Employing the DBIM-TwIST Algorithm.

Authors:  Syed Ahsan; Ziwen Guo; Zhenzhuang Miao; Ioannis Sotiriou; Maria Koutsoupidou; Efthymios Kallos; George Palikaras; Panagiotis Kosmas
Journal:  Sensors (Basel)       Date:  2018-10-16       Impact factor: 3.576

Review 8.  Review of Microwaves Techniques for Breast Cancer Detection.

Authors:  Maged A Aldhaeebi; Khawla Alzoubi; Thamer S Almoneef; Saeed M Bamatraf; Hussein Attia; Omar M Ramahi
Journal:  Sensors (Basel)       Date:  2020-04-22       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.