Literature DB >> 25532080

Endoscopic mucosal resection for middle and large colorectal polyps with a double-loop snare.

Naohisa Yoshida1, Yutaka Saito, Ryohei Hirose, Kiyoshi Ogiso, Yutaka Inada, Nobuaki Yagi, Yuji Naito, Yosuke Otake, Takeshi Nakajima, Takahisa Matsuda, Akio Yanagisawa, Yoshito Itoh.   

Abstract

BACKGROUND/AIMS: This study aimed to analyze the endoscopic mucosal resection (EMR) with a novel uniquely shaped, double-loop snare (Dualoop, Medico's Hirata Inc., Tokyo, Japan) for colorectal polyps.
METHODS: This was a clinical trial conducted in two referral centers, Kyoto Prefectural University of Medicine and National Cancer Center Hospital in Japan. First, the firmness of various snares including 'Dualoop' was experimentally analyzed with a pressure gauge. Five hundred and eighty nine consecutive polyps that underwent EMR with 'Dualoop' were compared to 339 polyps with the standard round snare. Lesion characteristics, en bloc resection, and complications were analyzed.
RESULTS: 'Dualoop' had the most firmness among the various snares. The average tumor size was 9.3 mm (5-30), and en bloc resection was achieved in 95.4%. The rate of en bloc resection for middle polyps 15-19 mm in diameter was significantly higher with the 'Dualoop' than that with the round snare (97.9 vs. 80.0%, p < 0.05). The rate of en bloc resection was 64.7% for large polyps ≥20 mm in diameter using 'Dualoop'. Higher age, larger tumor size, and superficial polyps were associated with the failure of en bloc resection.
CONCLUSION: EMR with 'Dualoop' was effective for resecting both middle and large polyps en-bloc.
© 2014 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2014        PMID: 25532080     DOI: 10.1159/000368044

Source DB:  PubMed          Journal:  Digestion        ISSN: 0012-2823            Impact factor:   3.216


  1 in total

1.  Recurrence rates after endoscopic resection of large colorectal polyps: A systematic review and meta-analysis.

Authors:  Carola Rotermund; Roupen Djinbachian; Mahsa Taghiakbari; Markus D Enderle; Axel Eickhoff; Daniel von Renteln
Journal:  World J Gastroenterol       Date:  2022-08-07       Impact factor: 5.374