| Literature DB >> 25531001 |
Kenan Alkhalili1, Nohra Chalouhi2, Stavropoula Tjoumakaris2, David Hasan3, Robert M Starke4, Mario Zanaty2, Robert H Rosenwasser2, Pascal Jabbour5.
Abstract
Three recently published trials, MR RESCUE, IMS III, and SYNTHESIS Expansion, evaluating the efficacy and safety of endovascular treatment of acute ischemic stroke have generated concerns about the future of endovascular approach. However, the tremendous evolution that imaging and endovascular treatment modalities have undergone over the past several years has raised doubts about the validity of these trials. In this paper, we review the role of endovascular treatment strategies in acute ischemic stroke and discuss the limitations and shortcomings that prevent generalization of the findings of recent trials. We also provide our experience in endovascular treatment of acute ischemic stroke.Entities:
Mesh:
Year: 2014 PMID: 25531001 PMCID: PMC4235257 DOI: 10.1155/2014/429549
Source DB: PubMed Journal: ScientificWorldJournal ISSN: 1537-744X
Recently published randomized trials of acute stroke therapies (design, limitations, and conclusions).
| Study | Subjects | Centers | Trial arms | Types of treatment | Flaws | Conclusions |
|---|---|---|---|---|---|---|
| IMS III | 656 | 58 | (1) IV rtPA; (2) IV rtPA + endovascular | tPA (0.9 mg per kilogram) | (1) Only 47% of enrolled patients had CT angiogram imaging at the time of enrollment | Comparable safety outcomes and no significant difference in functional independence with endovascular therapy after intravenous tPA, as compared with intravenous tPA alone |
|
| ||||||
| MR RESCUE | 127 | 22 | (1) Good penumbral pattern + thrombectomy | Merci retriever, Penumbra system | (1) Only included first-generation endovascular thrombectomy technologies | (1) A favorable penumbral pattern on neuroimaging did not identify patients who would differentially benefit from endovascular therapy |
|
| ||||||
| SYNTHESIS Expansion | 362 | (1) IV rtPA | Wire manipulation, IA rtPA, Merci retriever, Penumbra system, and Solitaire stent retrievers | (1) No preprocedural imaging was obtained to confirm LVO | No difference in functional outcome, safety, or mortality between the trial arms | |
|
| ||||||
| SWIFT | 144 | 18 | (1) Solitaire (stent-retriever thrombectomy) | Solitaire stent retriever, Merci retriever | — | The Solitaire Flow Restoration Device achieved substantially better angiographic, safety, and clinical outcomes than did the Merci Retrieval System |
|
| ||||||
| Trevo 2 | 178 | 27 | (1) Trevo (stent-retriever thrombectomy) | Trevo stent retriever, Merci retriever | Trevo retrievers achieved substantially better angiographic and clinical outcomes than did the Merci Retrieval System; safety endpoint did not differ between the trial arms | |
Figure 1Trial arms of recently published randomized trials of acute stroke treatment.