Corner cube retroreflectors are objects with three mutually perpendicular reflective surfaces that return light directly to its source and are therefore extremely bright and easy to detect. In this work, we have fabricated suspended corner cube retroreflectors, 5 microns in size, consisting of a transparent epoxy core and three surfaces coated with gold as ultra-bright labels for use in a rapid, low-labor diagnostic platform. The authors have demonstrated that individual cubes are easily imaged using low-cost, low numerical aperture objectives in suspension and that they remain suspended over long periods of time. Moreover, we have demonstrated that the gold outer surfaces can be decorated with proteins, and that individual cubes can be bound to magnetic sample preparation particles bearing antibodies which recognize these proteins. The bound cubes can be imaged and tracked as they move through solution in response to an external magnetic field, and we have, as such, demonstrated the principle of the new biosensing approach.

Entities:  

Year:  2011        PMID: 25530695      PMCID: PMC4269273          DOI: 10.1116/1.3656801

Source DB:  PubMed          Journal:  J Vac Sci Technol B Nanotechnol Microelectron        ISSN: 2166-2746


  13 in total

Review 1.  Nanomaterial enabled biosensors for pathogen monitoring - a review.

Authors:  Peter J Vikesland; Krista R Wigginton
Journal:  Environ Sci Technol       Date:  2010-05-15       Impact factor: 9.028

Review 2.  Lab-on-a-chip based immunosensor principles and technologies for the detection of cardiac biomarkers: a review.

Authors:  Mazher-Iqbal Mohammed; Marc P Y Desmulliez
Journal:  Lab Chip       Date:  2010-12-23       Impact factor: 6.799

3.  Analysis and fabrication of corner cube array based on laser direct writing technology.

Authors:  Yimin Lou; Hui Wang; Qingkun Liu; Yaocheng Shi; Sailing He
Journal:  Appl Opt       Date:  2010-10-10       Impact factor: 1.980

Review 4.  Functional nanoprobes for ultrasensitive detection of biomolecules.

Authors:  Shiping Song; Yu Qin; Yao He; Qing Huang; Chunhai Fan; Hong-Yuan Chen
Journal:  Chem Soc Rev       Date:  2010-09-24       Impact factor: 54.564

5.  Gold nanoparticle-quantum dot-polystyrene microspheres as fluorescence resonance energy transfer probes for bioassays.

Authors:  Ashley D Quach; Georgeta Crivat; Matthew A Tarr; Zeev Rosenzweig
Journal:  J Am Chem Soc       Date:  2011-01-31       Impact factor: 15.419

6.  Effects of retroreflector positioning on nighttime recognition of pedestrians.

Authors:  J Luoma; J Schumann; E C Traube
Journal:  Accid Anal Prev       Date:  1996-05

7.  Direct fabrication and harvesting of monodisperse, shape-specific nanobiomaterials.

Authors:  Jason P Rolland; Benjamin W Maynor; Larken E Euliss; Ansley E Exner; Ginger M Denison; Joseph M DeSimone
Journal:  J Am Chem Soc       Date:  2005-07-20       Impact factor: 15.419

8.  Nanoparticle-based bio-bar codes for the ultrasensitive detection of proteins.

Authors:  Jwa-Min Nam; C Shad Thaxton; Chad A Mirkin
Journal:  Science       Date:  2003-09-26       Impact factor: 47.728

9.  Lunar laser ranging: a continuing legacy of the apollo program.

Authors:  J O Dickey; P L Bender; J E Faller; X X Newhall; R L Ricklefs; J G Ries; P J Shelus; C Veillet; A L Whipple; J R Wiant; J G Williams; C F Yoder
Journal:  Science       Date:  1994-07-22       Impact factor: 47.728

10.  Single-molecule enzyme-linked immunosorbent assay detects serum proteins at subfemtomolar concentrations.

Authors:  David M Rissin; Cheuk W Kan; Todd G Campbell; Stuart C Howes; David R Fournier; Linan Song; Tomasz Piech; Purvish P Patel; Lei Chang; Andrew J Rivnak; Evan P Ferrell; Jeffrey D Randall; Gail K Provuncher; David R Walt; David C Duffy
Journal:  Nat Biotechnol       Date:  2010-05-23       Impact factor: 54.908

View more
  5 in total

1.  Detection and Monitoring of Microparticles Under Skin by Optical Coherence Tomography as an Approach to Continuous Glucose Sensing Using Implanted Retroreflectors.

Authors:  Shang Wang; Tim Sherlock; Betsy Salazar; Narendran Sudheendran; Ravi Kiran Manapuram; Katerina Kourentzi; Paul Ruchhoeft; Richard C Willson; Kirill V Larin
Journal:  IEEE Sens J       Date:  2013-11-01       Impact factor: 3.301

2.  An embedded microretroreflector-based microfluidic immunoassay platform.

Authors:  Balakrishnan Raja; Carmen Pascente; Jennifer Knoop; David Shakarisaz; Tim Sherlock; Steven Kemper; Katerina Kourentzi; Ronald F Renzi; Anson V Hatch; Juan Olano; Bi-Hung Peng; Paul Ruchhoeft; Richard Willson
Journal:  Lab Chip       Date:  2016-04-26       Impact factor: 6.799

3.  High-throughput top-down fabrication of uniform magnetic particles.

Authors:  Julia Litvinov; Azeem Nasrullah; Timothy Sherlock; Yi-Ju Wang; Paul Ruchhoeft; Richard C Willson
Journal:  PLoS One       Date:  2012-05-31       Impact factor: 3.240

4.  Microretroreflector-sedimentation immunoassays for pathogen detection.

Authors:  Gavin Garvey; David Shakarisaz; Federico Ruiz-Ruiz; Anna E V Hagström; Balakrishnan Raja; Carmen Pascente; Archana Kar; Katerina Kourentzi; Marco Rito-Palomares; Paul Ruchhoeft; Richard C Willson
Journal:  Anal Chem       Date:  2014-08-26       Impact factor: 6.986

5.  Flexible corner cube retroreflector array for temperature and strain sensing.

Authors:  Muhammad Waqas Khalid; Rajib Ahmed; Ali K Yetisen; Haider Butt
Journal:  RSC Adv       Date:  2018-02-16       Impact factor: 4.036

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.