QCM-D providing new horizon in the domain of sensitivity range and information for haemostasis of human plasma.

Munawar Hussain1, Hinnak Northoff2, Frank K Gehring3.   

Abstract

Monitoring of the haemostasis status is significant for proper therapeutic directions and decisions in surgery and innate coagulation disorders. In this regard, to gain a general overview of the plasmatic coagulation, prothrombin time (PT) tests are frequently combined with tests for activated partial thromboplastin time (aPTT). For aPTT we report for the first time that a QCM-D (Quartz Crystal Microbalances with Dissipation) based technique offers a better alternative to the standard coagulometer method in the perspective of range and information. We used heparin as anticoagulant to generate different coagulation times for human plasma. QCM-D astonishingly proved to be more sensitive and reliable than the standard coagulometer for aPTT range of upper limits of coagulation times. The established platform can monitor the fibrinogen concentration ranging from 1-6g/L (yielding R(2)=0.98 in calibration curves) along with aPTT from frequency and dissipation shifts together in a single set of measurements. Additionally the sensor layers have been tested for reusability, demonstrating no loss in sensor characteristics up to ten times measurements.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fibrinogen; Plasma; QCM-D; aPTT; qCell T

Mesh:

Substances:

Year:  2014        PMID: 25530537     DOI: 10.1016/j.bios.2014.12.003

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods.

Authors:  Stephanie Oberfrank; Hartmut Drechsel; Stefan Sinn; Hinnak Northoff; Frank K Gehring
Journal:  Sensors (Basel)       Date:  2016-02-24       Impact factor: 3.576

2.  ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation.

Authors:  Da Chen; Zhen Zhang; Jilong Ma; Wei Wang
Journal:  Sensors (Basel)       Date:  2017-05-03       Impact factor: 3.576

3.  Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method.

Authors:  Jia Yao; Bin Feng; Zhiqi Zhang; Chuanyu Li; Wei Zhang; Zhen Guo; Heming Zhao; Lianqun Zhou
Journal:  Sensors (Basel)       Date:  2018-09-13       Impact factor: 3.576

4.  Shear Mode Bulk Acoustic Resonator Based on Inclined c-Axis AlN Film for Monitoring of Human Hemostatic Parameters.

Authors:  Shuren Song; Da Chen; Hongfei Wang; Chaohui Li; Wei Wang; Wangli Yu; Yanyan Wang; Qiuquan Guo
Journal:  Micromachines (Basel)       Date:  2018-09-30       Impact factor: 2.891

Review 5.  Evolving Paradigm of Prothrombin Time Diagnostics with Its Growing Clinical Relevance towards Cardio-Compromised and COVID-19 Affected Population.

Authors:  Anubhuti Saha; Ashutosh Bajpai; Vinay Krishna; Shantanu Bhattacharya
Journal:  Sensors (Basel)       Date:  2021-04-09       Impact factor: 3.576

6.  Measurement of the viscoelastic properties of blood plasma clot formation in response to tissue factor concentration-dependent activation.

Authors:  Ramji S Lakshmanan; Vitaly Efremov; James S O'Donnell; Anthony J Killard
Journal:  Anal Bioanal Chem       Date:  2016-06-16       Impact factor: 4.142

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.