Literature DB >> 25530465

Interrupted orthodontic force results in less root resorption than continuous force in human premolars as measured by microcomputed tomography.

Monika Sawicka1, Rossella Bedini, Piotr M Wierzbicki, Cornelis H Pameijer.   

Abstract

INTRODUCTION: Root resorption is an undesirable but very frequently occurring sequel of orthodontic treatment. The aim of this study was to compare root resorption caused by either continuous (CF) or interrupted (IF) orthodontic force.
MATERIAL AND METHODS: The study was performed on human subjects on 30 first upper and lower premolars scheduled for extraction for orthodontic reasons. During four weeks before extraction 12 teeth were subjected to either CF or IF. The force was generated by a segmental titanium-molybdenum alloy cantilever spring that was activated in buccal direction. Initially a force of 60 CentiNewton was used in both CF and IF groups, the force in the former, however, was reactivated every week for 4 weeks. There was no reactivation of force in the IF group after initial application. A morphometric analysis of root resorption was performed by microcomputed tomography and the extent of tooth movement was measured on stone casts. Furthermore, a Tartarate-Resistant Acidic Phosphatase activity (TRAP), the marker enzyme of osteoclasts and cementoclasts, was determined by histochemical method. The Mann-Whitney U test was used to compare the difference in measured parameters between treatment and control tooth groups.
RESULTS: The number of resorption craters was significantly higher and their average volume almost twice as large in the CF compared to the IF group (p < 0.05). However, the distance of tooth displacement was similar for both groups. Cementoclasts were detected with the TRAP technique on the surface of two teeth only; both were subjected to continuous force.
CONCLUSIONS: The use of IF leads to less destruction of root structure as opposed to continuous force while the same tooth movement was achieved.

Entities:  

Mesh:

Year:  2014        PMID: 25530465     DOI: 10.5603/FHC.a2014.0037

Source DB:  PubMed          Journal:  Folia Histochem Cytobiol        ISSN: 0239-8508            Impact factor:   1.698


  4 in total

1.  Selection and validation of reference genes by RT-qPCR for murine cementoblasts in mechanical loading experiments simulating orthodontic forces in vitro.

Authors:  Christian Niederau; Rogerio B Craveiro; Irma Azraq; Julia Brockhaus; Asisa Bastian; Christian Kirschneck; Michael Wolf
Journal:  Sci Rep       Date:  2020-07-02       Impact factor: 4.379

2.  Effect of the application of high-frequency mechanical vibration on tooth length concurrent with orthodontic treatment using clear aligners: A retrospective study.

Authors:  Khaled Farouk; Thoas Shipley; Tarek El-Bialy
Journal:  J Orthod Sci       Date:  2018-11-15

3.  External apical root resorption in non-extraction cases after clear aligner therapy or fixed orthodontic treatment.

Authors:  Jianru Yi; Jiani Xiao; Yu Li; Xiaobing Li; Zhihe Zhao
Journal:  J Dent Sci       Date:  2018-02-01       Impact factor: 2.080

Review 4.  Apical External Root Resorption and Repair in Orthodontic Tooth Movement: Biological Events.

Authors:  Liviu Feller; Razia A G Khammissa; George Thomadakis; Jeanine Fourie; Johan Lemmer
Journal:  Biomed Res Int       Date:  2016-03-29       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.