Optimal interpretative strategy for preoperative parathyroid scintigraphy.

Farshad M Bahador1, Hamid R Latifi, Stanley J Grossman, Umesh D Oza, Hui Xu, Landis K Griffeth.   

Abstract

PURPOSE: Our objective was to retrospectively compare various scintigraphic methods to determine their relative accuracies and interobserver variabilities in preoperative localization of single-gland disease in patients with primary hyperparathyroidism. PATIENTS AND METHODS: We studied 292 patients who underwent preoperative parathyroid scintigraphy and surgical resection between June 2002 and September 2008. Imaging included early and delayed pinhole Tc-MIBI imaging (including anterior oblique images), similar I imaging, and MIBI SPECT. Seven different imaging combinations were assessed as follows: early MIBI only, delayed MIBI only, comparison of dual-phase early and delayed MIBI, visual subtraction of early MIBI and I images, all planar images, SPECT only, and all planar and SPECT images (ALL). Each data set was reviewed by 2 of 4 experienced nuclear physicians without knowledge of clinical information or final diagnosis. Imaging results were compared with surgical outcomes.
RESULTS: The accuracy of ALL imaging for delineating abnormal/normal parathyroid glands by quadrant was 96%, 93%, 95%, and 95% for the 4 readers. The accuracies of visual subtraction of early MIBI and I images and all planar images were not significantly different from ALL for all 4 readers. All planar and SPECT images were significantly more accurate than early MIBI only, delayed MIBI only, or SPECT only for all 4 readers and better than comparison of dual-phase early and delayed MIBI for 3 of 4 readers.
CONCLUSIONS: A rigorous combination of multiple imaging approaches yielded high accuracies across multiple readers for localization of a single offending parathyroid gland, but a more limited technique using MIBI/I subtraction imaging with anterior and anterior oblique pinhole images provided similarly high accuracy and limited interobserver variation of accuracy.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25525929     DOI: 10.1097/RLU.0000000000000626

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  2 in total

1.  Preoperative [99mTc]MIBI SPECT/CT Interpretation Criteria for Localization of Parathyroid Adenomas-Correlation with Surgical Findings.

Authors:  Zohar Keidar; Elena Solomonov; Rachel Karry; Alex Frenkel; Ora Israel; Michal Mekel
Journal:  Mol Imaging Biol       Date:  2017-04       Impact factor: 3.488

2.  99mTc-Sestamibi/123I Subtraction SPECT/CT in Parathyroid Scintigraphy: Is Additional Pinhole Imaging Useful?

Authors:  Virpi Tunninen; Pekka Varjo; Tomi Kauppinen; Anu Holm; Hannu Eskola; Marko Seppänen
Journal:  Int J Mol Imaging       Date:  2017-10-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.