Literature DB >> 25523866

Prediction of small-for-gestational-age neonates: screening by fetal biometry at 30-34 weeks.

S Bakalis1, M Silva, R Akolekar, L C Poon, K H Nicolaides.   

Abstract

OBJECTIVE: To investigate the value of fetal biometry at 30-34 weeks' gestation in the prediction of delivery of small-for-gestational-age (SGA) neonates, in the absence of pre-eclampsia (PE).
METHODS: This was a screening study in 30 849 singleton pregnancies at 30-34 weeks' gestation, comprising 1727 that delivered SGA neonates with a birth weight < 5(th) percentile and 29 122 cases unaffected by SGA, PE or gestational hypertension. Multivariable logistic regression analysis was used to determine if screening by a combination of maternal factors and Z-scores of fetal head circumference (HC), abdominal circumference (AC) and femur length (FL) or estimated fetal weight (EFW) had a significant contribution to the prediction of SGA neonates.
RESULTS: Combined screening by maternal characteristics and obstetric history, with Z-scores of EFW at 30-34 weeks, predicted 79%, 87% and 92% of the SGA neonates that delivered < 5 weeks following assessment, with a birth weight < 10(th) , < 5(th) and < 3(rd) percentiles, respectively, at a 10% false-positive rate. The respective detection rates for the prediction of SGA neonates delivering ≥ 5 weeks from the time of assessment were 53%, 58% and 61%. The performance of screening by a combination of Z-scores of fetal HC, AC and FL was similar to that achieved by the EFW Z-score alone.
CONCLUSION: Combined testing by maternal characteristics and fetal biometry at 30-34 weeks could identify a high proportion of pregnancies that will deliver SGA neonates.
Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  abdominal circumference; estimated fetal weight; fetal biometry; pre-eclampsia; pyramid of antenatal care; small-for-gestational age; third-trimester screening

Mesh:

Year:  2015        PMID: 25523866     DOI: 10.1002/uog.14771

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

1.  Personalized Model to Predict Small for Gestational Age at Delivery Using Fetal Biometrics, Maternal Characteristics, and Pregnancy Biomarkers: A Retrospective Cohort Study of Births Assisted at a Spanish Hospital.

Authors:  Peña Dieste-Pérez; Ricardo Savirón-Cornudella; Mauricio Tajada-Duaso; Faustino R Pérez-López; Sergio Castán-Mateo; Gerardo Sanz; Luis Mariano Esteban
Journal:  J Pers Med       Date:  2022-05-08

2.  The Impact of Kidney Development on the Life Course: A Consensus Document for Action.

Authors: 
Journal:  Nephron       Date:  2017-03-21       Impact factor: 2.847

3.  Utility of Doppler parameters at 36-42 weeks' gestation in the prediction of adverse perinatal outcomes in appropriate-for-gestational-age fetuses.

Authors:  Michał Migda; Katarzyna Gieryn; Bartosz Migda; Marian Stanisław Migda; Marek Maleńczyk
Journal:  J Ultrason       Date:  2018-03-30

4.  Better prediction for FGR (fetal growth restriction) with the sFlt-1/PIGF ratio: A case-control study.

Authors:  Valeria Visan; Ioana Sadiye Scripcariu; Demetra Socolov; Amelia Costescu; Daniela Rusu; Razvan Socolov; Andreea Avasiloaiei; Lucian Boiculese; Cristina Dimitriu
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.