Literature DB >> 25523044

Temperature-controlled ionic liquid-based ultrasound-assisted microextraction for preconcentration of trace quantity of cadmium and nickel by using organic ligand in artificial saliva extract of smokeless tobacco products.

Sadaf Sadia Arain1, Tasneem Gul Kazi2, Asma Jabeen Arain3, Hassan Imran Afridi4, Jameel Ahmed Baig5, Kapil Dev Brahman6, Salma Aslam Arain7.   

Abstract

A new approach was developed for the preconcentration of cadmium (Cd) and nickel (Ni) in artificial saliva extract of dry snuff (brown and black) products using temperature-controlled ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (TIL-UDLLμE) followed by electrothermal atomic absorption spectrometry (ETAAS). The Cd and Ni were complexed with ammonium pyrrolidinedithiocarbamate (APDC), extracted in ionic liquid drops, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6]. The multivariate strategy was applied to estimate the optimum values of experimental variables influence the % recovery of analytes by TIL-UDLLμE method. At optimum experimental conditions, the limit of detection (3s) were 0.05 and 0.14μgL(-1) while relative standard deviations (% RSD) were 3.97 and 3.55 for Cd and Ni respectively. After extraction, the enhancement factors (EF) were 87 and 79 for Cd and Ni, respectively. The RSD for six replicates of 10μgL(-1) Cd and Ni were 3.97% and 3.55% respectively. To validate the proposed method, certified reference material (CRM) of Virginia tobacco leaves was analyzed, and the determined values of Cd and Ni were in good agreement with the certified values. The concentration of Cd and Ni in artificial saliva extracts corresponds to 39-52% and 21-32%, respectively, of the total contents of both elements in dry brown and black snuff products.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  1-Butyl-3-methylimidazolium hexafluorophosphate; Artificial saliva; Cadmium; Lead; Microextraction

Mesh:

Substances:

Year:  2014        PMID: 25523044     DOI: 10.1016/j.saa.2014.11.043

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  3 in total

1.  Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.

Authors:  Sadaf S Arain; Tasneem G Kazi; Asma J Arain; Hassan I Afridi; Muhammad B Arain; Kapil D Brahman; Abdul H Panhwar; Mariam S Arain
Journal:  Environ Sci Pollut Res Int       Date:  2015-04-23       Impact factor: 4.223

2.  Preconcentration and determination of lead and cadmium levels in blood samples of adolescent workers consuming smokeless tobacco products in Pakistan.

Authors:  Sadaf Sadia Arain; Tasneem Gul Kazi; Hassan Imran Afridi; Kapil Dev Brahman; Sumaira Khan; Abdul Haleem Panhwar; Muhammad Afzal Kamboh; Jamil R Memon
Journal:  Environ Monit Assess       Date:  2015-05-01       Impact factor: 2.513

3.  Methods of liquid phase microextraction for the determination of cadmium in environmental samples.

Authors:  Analú Pires Santos; Maria das Graças Andrade Korn; Valfredo Azevedo Lemos
Journal:  Environ Monit Assess       Date:  2017-08-09       Impact factor: 2.513

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.