Literature DB >> 25518877

Instability after total knee arthroplasty.

David Clinton McNabb1, Raymond H Kim1, Bryan D Springer2.   

Abstract

Total knee arthroplasty (TKA) has shown to portend good long-term survivorship and excellent patient satisfaction. There are various etiologies of failure of a TKA. Instability is a major cause of the need for revision. Often, increased constraint is needed to supplement or perform the function of incompetent ligament and soft tissue structures. Posterior cruciate retaining (PCR) TKA has the least constraint. Posterior cruciate substituting (PS) TKA increases sagittal constraint. Varus-valgus constraint (VVC) adds a marked increase in coronal stability. The ultimate in constraint in TKA is a linked hinged implant. In revision TKA, it is the surgeon's responsibility to implant the prosthesis with the necessary constraint to impart adequate stability. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2014        PMID: 25518877     DOI: 10.1055/s-0034-1396080

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  8 in total

Review 1.  Current surgical strategies for total arthroplasty in valgus knee.

Authors:  Dimitrios Nikolopoulos; Ioannis Michos; George Safos; Petros Safos
Journal:  World J Orthop       Date:  2015-07-18

2.  The role of ligament tension and sensomotoric system in total knee arthroplasty.

Authors:  Roland Becker; Michael Tobias Hirschmann; Jon Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-06       Impact factor: 4.342

3.  KNEE ARTHROPLASTY REVISION WITH A CONSTRAINED IMPLANT USING HINGE AND ROTATING TIBIAL BASIS.

Authors:  Fabio Jansen Angelini; Camilo Partezani Helito; Bruno Azevedo Veronesi; Tales Mollica Guimarães; José Ricardo Pécora; Marco Kawamura Demange
Journal:  Acta Ortop Bras       Date:  2016 Jan-Feb       Impact factor: 0.513

Review 4.  [The Berlin diagnostic algorithm for painful knee TKA].

Authors:  K Thiele; J Fussi; C Perka; T Pfitzner
Journal:  Orthopade       Date:  2016-01       Impact factor: 1.087

5.  Is gap balancing superior to measured resection technique in total knee arthroplasty? A meta-analysis.

Authors:  Qiang He; Caihong Sun; Jianbing Ma; Jianbing Guo
Journal:  Arthroplasty       Date:  2020-01-29

6.  Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report.

Authors:  Abdulaziz Alkheraiji; Sultana Borai; Rheema Alfadhil; Fawzi AlJassir
Journal:  Int J Surg Case Rep       Date:  2022-07-23

7.  Verification and clinical translation of a newly designed "Skywalker" robot for total knee arthroplasty: A prospective clinical study.

Authors:  Runzhi Xia; Zanjing Zhai; Jingwei Zhang; Degang Yu; Liao Wang; Yuanqing Mao; Zhenan Zhu; Haishan Wu; Kerong Dai; Mengning Yan; Huiwu Li
Journal:  J Orthop Translat       Date:  2021-06-24       Impact factor: 5.191

8.  What role does metal allergy sensitization play in total knee arthroplasty revision?

Authors:  David R Lionberger; Justin Samorajski; Charlie D Wilson; Andreana Rivera
Journal:  J Exp Orthop       Date:  2018-08-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.