Literature DB >> 25517186

Detection of gaseous compounds by needle trap sampling and direct thermal-desorption photoionization mass spectrometry: concept and demonstrative application to breath gas analysis.

Juliane Kleeblatt1, Jochen K Schubert, Ralf Zimmermann.   

Abstract

A fast detection method to analyze gaseous organic compounds in complex gas mixtures was developed, using a needle trap device (NTD) in conjunction with thermal-desorption photoionization time-of-flight mass spectrometry (TD-PI-TOFMS). The mass spectrometer was coupled via a deactivated fused silica capillary to an injector of a gas chromatograph. In the hot injector, the analytes collected on the NTD were thermally desorbed and directly transferred to the PI-TOFMS ion source. The molecules are softly ionized either by single photon ionization (SPI, 118 nm) or by resonance enhanced multiphoton ionization (REMPI, 266 nm), and the molecular ion signals are detected in the TOF mass analyzer. Analyte desorption and the subsequent PI-TOFMS detection step only lasts ten seconds. The specific selectivity of REMPI (i.e., aromatic compounds) and universal ionization characteristics render PI-MS as a promising detection system. As a first demonstrative application, the alveolar phase breath gas of healthy, nonsmoking subjects was sampled on NTDs. While smaller organic compounds such as acetone, acetaldehyde, isoprene, or cysteamine can be detected in the breath gas with SPI, REMPI depicts the aromatic substances phenol and indole at 266 nm. In the breath gas of a healthy, smoking male subject, several xenobiotic substances such as benzene, toluene, styrene, and ethylbenzene can be found as well. Furthermore, the NTD-REMPI-TOFMS setup was tested for breath gas taken from a mechanically ventilated pig under continuous intravenous propofol (2,6-diisopropylphenol, narcotic drug) infusion.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25517186     DOI: 10.1021/ac5039829

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Effects of Solvent and Ion Source Pressure on the Analysis of Anabolic Steroids by Low Pressure Photoionization Mass Spectrometry.

Authors:  Chengyuan Liu; Yanan Zhu; Jiuzhong Yang; Wan Zhao; Deen Lu; Yang Pan
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-24       Impact factor: 3.109

2.  Real-time Simutaneous Separation and Detection of Chemicals using Integrated Micro Column and Surface Plasmon Resonance Imaging Micro-GC.

Authors:  Zijian Du; Francis Tsow; Di Wang; Nongjian Tao
Journal:  IEEE Sens J       Date:  2017-12-15       Impact factor: 3.301

3.  Porcine pancreas mesenchymal cell characterization and functional differentiation into insulin‑producing cells in vitro.

Authors:  Shang Zhang; Qi Wang; Hongbing Ji; Huidi Lu; Qin Yang; Jiahui Yin; Weijun Guan
Journal:  Mol Med Rep       Date:  2021-08-20       Impact factor: 2.952