Radial artery cannulation decreases the distal arterial blood flow measured by power Doppler ultrasound.

Atsushi Numaguchi1,2, Yushi U Adachi3, Yoshitaka Aoki4, Yasuhiro Ishii5, Katsumi Suzuki6, Yukako Obata7, Shigehito Sato7, Kimitoshi Nishiwaki8, Naoyuki Matsuda9.   

Abstract

Radial arterial cannulation is a popular technique for continuous hemodynamic monitoring in an area of anesthesia and intensive care. Although the risk for invasive monitoring is considerable, there is scarce information about the change in blood flow of cannulated vessel after the catheterization. In the current investigation, we evaluated the change in the cannulated arterial blood flow. Six volunteers (study 1) and eight post-surgical patients (study 2) were enrolled into the studies. In the study 1, the both side of diameter of radial artery (RA), ulnar artery (UA) and dorsal branch of radial artery (DBRA) of participants were measured using power Doppler ultrasound (PDU) with or without proximal oppression. In the study 2, the diameter of RA, UA and DBRA of the both intact and cannulated side were compared. Study 1: The diameter of RA was 3.4 (0.52) [mean (SD)] mm and the proximal oppression significantly decreased the diameter to 1.8 (0.59) mm. The diameter of DBRA measured by PDU also decreased 2.0 (0.60)-1.3 (0.59) mm. Study 2: There was no difference between the diameters of right and left RA, however, the UA was larger [3.4 (0.60) vs. 2.8 (0.83) mm] and the DBRA was narrower [1.4 (0.43) vs. 2.0 (0.47) mm] in the cannulated side. The diameters of DBRA were different between the intact and cannulated side in the patients. Although there is no information of relationships between cause of severe complication and decreased flow, significant reduction of blood flow should be concerned.

Entities:  

Keywords:  Blood flow; Cannulation; Radial artery; Ultrasound sonography

Mesh:

Year:  2014        PMID: 25516161     DOI: 10.1007/s10877-014-9648-5

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  11 in total

1.  Preoperative assessment of hand circulation by means of Doppler ultrasonography and the modified Allen test.

Authors:  P Ruengsakulrach; M Brooks; D L Hare; I Gordon; B F Buxton
Journal:  J Thorac Cardiovasc Surg       Date:  2001-03       Impact factor: 5.209

2.  Lest we forget: learning and remembering in clinical practice.

Authors:  A Smith
Journal:  Anaesthesia       Date:  2013-09-05       Impact factor: 6.955

Review 3.  Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations.

Authors:  Marek Brzezinski; Thomas Luisetti; Martin J London
Journal:  Anesth Analg       Date:  2009-12       Impact factor: 5.108

Review 4.  Transradial cardiac catheterization: a review of access site complications.

Authors:  Yumiko Kanei; Tak Kwan; Navin C Nakra; Michael Liou; Yili Huang; Lori L Vales; John T Fox; Jack P Chen; Shigeru Saito
Journal:  Catheter Cardiovasc Interv       Date:  2011-05-12       Impact factor: 2.692

5.  Evaluation of radial and ulnar blood flow after radial artery cannulation with 20- and 22-gauge cannulae using duplex Doppler ultrasound.

Authors:  S Y Kim; J S Lee; W O Kim; J M Sun; M K Kwon; H K Kil
Journal:  Anaesthesia       Date:  2012-07-16       Impact factor: 6.955

6.  Chronic compensatory increase in ulnar flow and accelerated atherosclerosis after radial artery removal for coronary artery bypass.

Authors:  Mario Gaudino; Michele Serricchio; Paolo Tondi; Laura Gerardino; Angela Di Giorgio; Paolo Pola; Gianfederico Possati
Journal:  J Thorac Cardiovasc Surg       Date:  2005-07       Impact factor: 5.209

7.  Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients.

Authors:  E E Frezza; H Mezghebe
Journal:  Am Surg       Date:  1998-02       Impact factor: 0.688

8.  On the safety of radial artery cannulation.

Authors:  S Slogoff; A S Keats; C Arlund
Journal:  Anesthesiology       Date:  1983-07       Impact factor: 7.892

9.  The impact of two arterial catheters, different in diameter and length, on postcannulation radial artery diameter, blood flow, and occlusion in atherosclerotic patients.

Authors:  H Evren Eker; Acar Tuzuner; Ali Abbas Yilmaz; Zekeriyya Alanoglu; Yesim Ates
Journal:  J Anesth       Date:  2009-08-14       Impact factor: 2.078

Review 10.  Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.

Authors:  Bernd Scheer; Azriel Perel; Ulrich J Pfeiffer
Journal:  Crit Care       Date:  2002-04-18       Impact factor: 9.097

View more
  2 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Accuracy of Continuous and Noninvasive Hemoglobin Monitoring in the Presence of CO2 Insufflation: An Observational Pilot Study.

Authors:  Hye Sun Lee; Ji Won Yoo; Ha Yeon Kim; Na Young Kim; Ji Eun Kim
Journal:  Med Sci Monit       Date:  2021-10-27
  2 in total