Literature DB >> 25514870

A computational fluid dynamics comparison between different outflow graft anastomosis locations of Left Ventricular Assist Device (LVAD) in a patient-specific aortic model.

Maria Vittoria Caruso1, Vera Gramigna, Michele Rossi, Giuseppe Filiberto Serraino, Attilio Renzulli, Gionata Fragomeni.   

Abstract

Left ventricular assist devices (LVADs) are mechanical supports used in case of heart failure. Little is known as the height of the anastomosis in aorta might influence the hemodynamic. The aim of the study was to evaluate the fluid dynamic behavior due to the outflow graft placement of a continuous flow LVAD in ascending aorta and to identify the insertion site with the best hemodynamic profile. Computational fluid dynamic studies were carried out to analyze 4 different anastomosis locations in a patient-specific aorta 3D model coupled with a lumped parameters model: 1 cm (case 1), 2 cm (case 2), 3 cm (case 3) and 4 cm (case 4) above the ST junction. In cases 1 and 2, epiaortic vessels presented a steady flow, while in cases 3 and 4 the flow was whirling. Moreover, maximum velocity occurred before: brachiocephalic trunk (case 1), brachiocephalic and left carotid arteries (case 2), left carotid and left subclavian artery (case 3) and left subclavian vessel and upper wall of aortic arch (case 4). Maximum time averaged wall shear stress (TAWSS) was located in: the ascending aorta (cases 1 and 2), the inferior curvature of the arch (case 3); at the origin of epiaortic vessels (case 4). Furthermore, a flow recirculation (cases 1 and 2), a blood stagnation and chaotic flow (cases 3 and 4) occurred above the aortic valve. The results suggested that the placement of the outflow graft at 2 cm above the ST junction gave the most favorable hemodynamic profile.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  aorta; computational fluid dynamic; hemodynamic; left ventricular assist device; lumped parameters model

Mesh:

Year:  2015        PMID: 25514870     DOI: 10.1002/cnm.2700

Source DB:  PubMed          Journal:  Int J Numer Method Biomed Eng        ISSN: 2040-7939            Impact factor:   2.747


  3 in total

1.  The study on hemodynamic effect of series type LVAD on aortic blood flow pattern: a primary numerical study.

Authors:  Qi Zhang; Bin Gao; Yu Chang
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

2.  Helical Flow Component of Left Ventricular Assist Devices (LVADs) Outflow Improves Aortic Hemodynamic States.

Authors:  Qi Zhang; Bin Gao; Yu Chang
Journal:  Med Sci Monit       Date:  2018-02-12

3.  Patient-Specific Computational Fluid Dynamics Reveal Localized Flow Patterns Predictive of Post-Left Ventricular Assist Device Aortic Incompetence.

Authors:  Rohan Shad; Alexander D Kaiser; Sandra Kong; Robyn Fong; Nicolas Quach; Cayley Bowles; Patpilai Kasinpila; Yasuhiro Shudo; Jeffrey Teuteberg; Y Joseph Woo; Alison L Marsden; William Hiesinger
Journal:  Circ Heart Fail       Date:  2021-06-18       Impact factor: 10.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.