Literature DB >> 25506659

Retentiveness of various luting agents used with implant-supported prosthesis: an in vitro study.

Pooja Garg1, Malesh Pujari, D R Prithviraj, Sumit Khare.   

Abstract

Desired retrievability of cemented implant-supported fixed prosthesis makes the retentive strength of cementing agents an important consideration. The aim of the study was to evaluate the retentiveness of purposely designed implant cement and compare its retentiveness with dental cements that are commonly used with implant systems. Ten implant analogs were embedded in auto-polymerizing acrylic resin blocks and titanium abutments were attached to them. Fifty standardized copings were waxed directly on the abutment and casted. The cements used were: (1) resin-bonded zinc oxide eugenol cement, (2) purposely designed implant cement, (3) zinc phosphate cement, (4) zinc polycarboxylate cement, and (5) glass ionomer cement. After cementation, each sample was subjected to a pull-out test using universal testing machine and loads required to remove the crowns were recorded. The mean values and standard deviations of cement failure loads were analyzed using ANOVA and Bonferroni test. The mean values (± SD) of loads at failure (n = 10) for various cements were as follows (N): resin-bonded zinc oxide eugenol cement 394.62 (± 9.76), Premier implant cement 333.86 (± 18.91), zinc phosphate cement 629.30 (± 20.65), zinc polycarboxylate cement 810.08 (± 11.52), and glass ionomer cement 750.17 (± 13.78). The results do not suggest that one cement type is better than another, but they do provide a ranking order of the cements regarding their ability to retain the prosthesis and facilitate easy retrievability.

Entities:  

Keywords:  cement failure load; dental cement; implant supported prosthesis; retentive strength and retrievability

Mesh:

Substances:

Year:  2014        PMID: 25506659     DOI: 10.1563/AAID-JOI-D-12-00008

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  5 in total

1.  Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

Authors:  Sina Safari; Fereshteh Hosseini Ghavam; Parviz Amini; Kaveh Yaghmaei
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

2.  Evaluation of the Effect of Fluoride-containing Luting Cements on Titanium and Its Effect on the Shear Bond Strength.

Authors:  Kondumahanti V N Avinash; Vahini Reddy; Jayakar Shetty; H C Nitin
Journal:  Contemp Clin Dent       Date:  2019 Jan-Mar

3.  The effect of different cleansing methods for removing temporary cement on the tensile bond force of permanently cemented implant-supported metal copings: An in vitro study.

Authors:  Behnaz Ebadian; Mohammad Jowkar; Amin Davoudi; Amirhossein Fathi; Mohsen Ziaei; Einar Berg
Journal:  Clin Exp Dent Res       Date:  2022-05-26

4.  Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study.

Authors:  Jae-Won Choi; Kyung-Hee Choi; Hee-Jin Chae; Sung-Ki Chae; Eun-Bin Bae; Jin-Ju Lee; So-Hyoun Lee; Chang-Mo Jeong; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2018-04-06       Impact factor: 3.623

5.  Influence of Non-Thermal Atmospheric Pressure Plasma Treatment on Retentive Strength between Zirconia Crown and Titanium Implant Abutment.

Authors:  Dae-Sung Kim; Jong-Ju Ahn; Gyoo-Cheon Kim; Chang-Mo Jeong; Jung-Bo Huh; So-Hyoun Lee
Journal:  Materials (Basel)       Date:  2021-05-01       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.