Literature DB >> 25506194

Light-Sharing Interface for dMiCE Detectors using Sub-Surface Laser Engraving.

William C J Hunter1, Robert S Miyaoka1, Lawrence MacDonald1, Wendy McDougald1, Thomas K Lewellen1.   

Abstract

We have previously reported on dMiCE, a method of resolving depth or interaction (DOI) in a pair of discrete crystals by encoding light sharing properties as a function of depth in the interface of this crystal-element pair. A challenge for this method is the cost and repeatability of interface treatment for a crystal pair. In this work, we report our preliminary results on using sub-surface laser engraving (SSLE) as a means of forming this depth-dependent interface in a dMiCE detector. A surplus first-generation SSLE system was used to create a partially reflective layer 100-microns thick at the boundary between two halves of a 1.4-by-2.9-by-20 mmˆ3 LYSO crystal. The boundary of these paired crystal elements was positioned between two 3-mm wide Geiger-Müller avalanche photodiodes from Hamamatsu. The responses of these two photodetectors were acquired for an ensemble of 511-keV photons collimated to interact at a fixed depth in just one crystal element. Interaction position was then varied to measure detector response as a function of depth, which was then used to maximum-likelihood positions events. Despite use of sub-optimal SSLE processing we found an average DOI resolution of 3.4 mm for front-sided readout and 3.9 mm for back-sided readout. We expect DOI resolution can be improved significantly by optimizing the SSLE process and pattern.

Entities:  

Year:  2013        PMID: 25506194      PMCID: PMC4264536          DOI: 10.1109/NSSMIC.2013.6829407

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  4 in total

1.  New Directions for dMiCE - a Depth-of-Interaction Detector Design for PET Scanners.

Authors:  T K Lewellen; L R Macdonald; R S Miyaoka; W McDougald; K Champley
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

2.  Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors.

Authors:  Yoshiyuki Hirano; Naoko Inadama; Eiji Yoshida; Fumihiko Nishikido; Hideo Murayama; Mitsuo Watanabe; Taiga Yamaya
Journal:  Phys Med Biol       Date:  2013-02-08       Impact factor: 3.609

3.  SCOUT: a fast Monte-Carlo modeling tool of scintillation camera output.

Authors:  William C J Hunter; Harrison H Barrett; John P Muzi; Wendy McDougald; Lawrence R MacDonald; Robert S Miyaoka; Thomas K Lewellen
Journal:  Phys Med Biol       Date:  2013-05-02       Impact factor: 3.609

4.  Maximum-Likelihood Methods for Processing Signals From Gamma-Ray Detectors.

Authors:  Harrison H Barrett; William C J Hunter; Brian William Miller; Stephen K Moore; Yichun Chen; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.