Literature DB >> 25503651

Effects of three month nasal continuous positive airway pressure treatment on electrocardiographic, echocardiographic and overnight polysomnographic parameters in newly diagnosed moderate/severe obstructive sleep apnea patients.

Davran Cicek1, Akif Serhat Balcioğlu, Hüseyin Lakadamyali, Haldun Müderrisoğlu.   

Abstract

The objective of the study was to determine the effects of nasal continuous positive airway pressure (nCPAP) therapy on left ventricular (LV) function and electrocardiographic parameters in newly diagnosed moderate/severe obstructive sleep apnea (OSA) patients without cardiovascular comorbidities and medical treatments. We examined 44 patients who underwent overnight polysomnography together with 24-hour Holter electrocardiography, cardiopulmonary exercise testing including heart rate recovery at 1 minute (HRR-1), echocardiography, surface electrocardiography, and those who were diagnosed with moderate/severe OSA apnea--hypopnea index ≥ 15. After 3 months of nCPAP treatment, the above-mentioned examinations were repeated. Forty-four patients completed the treatment period. Twelve weeks on effective nCPAP induced a significant increase in the mitral E/A ratio (P = 0.001), as well as reductions in isovolumic relaxation time (P = 0.001) and mitral deceleration time (DT) (P = 0.002). There were no significant differences in LV ejection fraction, LV mass index, and pulsed wave Doppler parameters. Mean heart rate was 79.2 ± 12.5 pulses/minute, maximum P-wave duration 117.5 ± 8.6 msec, P-wave dispersion (PWd) 54.6 ± 10.2 msec, corrected QT interval (QTc) 436.5 ± 40.5 msec, and QT dispersion (QTd) 46.3 ± 7.1 msec, which significantly decreased to 70.4 ± 9.6 pulses/minute (P < 0.001), 111.5 ± 8.7 msec (P < 0.001), 51.6 ± 8.9 msec (P < 0.001), 418.4 ± 31.2 msec (P < 0.001), and 33.8 ± 3.4 msec (P < 0.001), respectively. Exercise capacity at baseline determined as 10.5 ± 2.2 metabolic equivalents (METS) and HRR-1 (20.6 ± 11.7 bpm) significantly increased (12.1 ± 1.5 METS and 27.4 ± 8.6 bpm). There was no significant difference in aortic root parameters. Three-month nCPAP therapy significantly increased LV shortening fraction, with no effect on systolic function or aortic root diameters and a positive effect on heart rate, PWd, HRR-1, QTc and QTd time following nCPAP therapy.

Entities:  

Mesh:

Year:  2014        PMID: 25503651     DOI: 10.1536/ihj.14-085

Source DB:  PubMed          Journal:  Int Heart J        ISSN: 1349-2365            Impact factor:   1.862


  5 in total

1.  QTc prolongation is associated with severe desaturations in stroke patients with sleep apnea.

Authors:  Saara Sillanmäki; Jukka A Lipponen; Henri Korkalainen; Antti Kulkas; Timo Leppänen; Sami Nikkonen; Juha Töyräs; Brett Duce; Aaron Suni; Samu Kainulainen
Journal:  BMC Pulm Med       Date:  2022-05-24       Impact factor: 3.320

2.  Pulmonary Artery Distensibility is Worsened in Obstructive Sleep Apnea Syndrome.

Authors:  Emir Karacaglar; Ugur Bal; Serpil Eroglu; Ayse Colak; Serife Bozbas; Haldun Muderrisoglu
Journal:  Acta Cardiol Sin       Date:  2019-09       Impact factor: 2.672

Review 3.  P-wave dispersion: an update.

Authors:  Andrés Ricardo Pérez-Riera; Luiz Carlos de Abreu; Raimundo Barbosa-Barros; José Grindler; Acácio Fernandes-Cardoso; Adrian Baranchuk
Journal:  Indian Pacing Electrophysiol J       Date:  2016-10-20

4.  Potent hERG channel inhibition by sarizotan, an investigative treatment for Rett Syndrome.

Authors:  Hongwei Cheng; Chunyun Du; Yihong Zhang; Andrew F James; Christopher E Dempsey; Ana P Abdala; Jules C Hancox
Journal:  J Mol Cell Cardiol       Date:  2019-07-27       Impact factor: 5.000

5.  Aortic Root Diameter in Hypertensive Patients With Various Stages of Obstructive Sleep Apnea.

Authors:  Dian Wang; Jian-Zhong Xu; Yuan-Yuan Kang; Wei Zhang; Lei-Xiao Hu; Ji-Guang Wang
Journal:  Am J Hypertens       Date:  2022-02-01       Impact factor: 2.689

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.