Literature DB >> 25502167

Early neointimal coverage and vasodilator response following biodegradable polymer sirolimus-eluting vs. durable polymer zotarolimus-eluting stents in patients with acute coronary syndrome –HATTRICK-OCT trial.

Pasi P Karjalainen1, Ville Varho, Wail Nammas, Jussi Mikkelsson, Mikko Pietilä, Antti Ylitalo, Juhani K E Airaksinen, Jussi Sia, Kai Nyman, Fausto Biancari, Tuomas Kiviniemi.   

Abstract

BACKGROUND: Patients at high bleeding risk would benefit from a shorter dual antiplatelet therapy after PCI. Compared to first-generation devices, the design of newer generation drug-eluting stents may facilitate more rapid anatomical and functional healing of stented vessel based on thinner stent platforms, biodegradable/biocompatible polymers and rapid drug elution. METHODS AND
RESULTS: Forty-four non-diabetic patients with acute coronary syndrome (ACS) and culprit lesion in the LAD were randomized to receive either biodegradable polymer sirolimus-eluting stent (BP-SES) or durable polymer zotarolimus-eluting stent (DP-ZES). Neointimal strut coverage was examined using optical coherence tomography, and vasodilator response on invasive thermodilution-derived coronary flow reserve (CFR) at 3-month follow-up. The primary endpoints were percent uncovered struts and CFR. A total of 425 cross-sections (4,897 struts) were analyzed in the BP-SES group, and 425 cross-sections (5,467 struts) in the DP-ZES group. The percent uncovered struts was lower in the BP-SES group compared with the DP-ZES group, both at strut level (3.9% vs. 8.9%, respectively, P<0.001), and stent level (3.9 ± 3.2% vs. 8.9 ± 6.9%, respectively, P=0.019). No significant difference was found between the 2 groups regarding CFR (3.0 ± 1.3 vs. 3.2 ± 1.0, respectively, P>0.05).
CONCLUSIONS: In non-diabetic patients with ACS, BP-SES provided slightly better stent strut coverage at 3 months compared with DP-ZES, but neither stent was fully covered. No difference in vasodilator response was seen.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25502167     DOI: 10.1253/circj.CJ-14-1000

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  7 in total

1.  Comparable neointimal healing in patients with stable coronary lesions and acute coronary syndrome: 3-month optical coherence tomography analysis.

Authors:  Yuma Hamanaka; Yohei Sotomi; Tomoaki Kobayashi; Takashi Omatsu; Jouke Dijkstra; Yasushi Sakata; Atsushi Hirayama; Akio Hirata; Yoshiharu Higuchi
Journal:  Int J Cardiovasc Imaging       Date:  2021-02-16       Impact factor: 2.357

Review 2.  Surrogate and clinical endpoints in interventional cardiology: are statistics the brakes?

Authors:  Matthias Waliszewski; Harald Rittger
Journal:  Ther Adv Cardiovasc Dis       Date:  2016-07-04

3.  Early vascular healing of ultra-thin strut polymer-free sirolimus-eluting stents in acute coronary syndrome: USUI-ACS study.

Authors:  Yutaka Matsuhiro; Yasuyuki Egami; Naotaka Okamoto; Masaya Kusuda; Takashige Sakio; Hiroaki Nohara; Hiroki Sugae; Shodai Kawanami; Akito Kawamura; Kohei Ukita; Hitoshi Nakamura; Koji Yasumoto; Masaki Tsuda; Yasuharu Matsunaga-Lee; Masamichi Yano; Masami Nishino; Jun Tanouchi
Journal:  Cardiovasc Interv Ther       Date:  2022-04-27

4.  Current State of Bioabsorbable Polymer-Coated Drug-Eluting Stents.

Authors:  Abhilash Akinapelli; Jack P Chen; Kristine Roy; Joseph Donnelly; Keith Dawkins; Barbara Huibregtse; Dongming Hou
Journal:  Curr Cardiol Rev       Date:  2017

Review 5.  Neoatherosclerosis after Drug-Eluting Stent Implantation: Roles and Mechanisms.

Authors:  Yuanyuan Cui; Yue Liu; Fuhai Zhao; Dazhuo Shi; Keji Chen
Journal:  Oxid Med Cell Longev       Date:  2016-06-30       Impact factor: 6.543

6.  Randomized Comparison of Strut Coverage between Ticagrelor and Clopidogrel in Acute Myocardial Infarction at 3-Month Optical Coherence Tomography.

Authors:  Choongki Kim; Byeong Keuk Kim; Sung Jin Hong; Chul Min Ahn; Jung Sun Kim; Young Guk Ko; Donghoon Choi; Myeong Ki Hong; Yangsoo Jang
Journal:  Yonsei Med J       Date:  2018-07       Impact factor: 2.759

7.  The comparison of early healing 1-month after PCI among CoCr-everolimus-eluting stent (EES), biodegradable polymer (BP)-EES and BP-sirolimus-eluting stent: Insights from OFDI and coronary angioscopy.

Authors:  Takao Sato; Yuji Taya; Naomasa Suzuki; Sho Yuasa; Shohei Kishi; Tomoyasu Koshikawa; Koichi Fuse; Satoshi Fujita; Yoshio Ikeda; Hitoshi Kitazawa; Minoru Takahashi; Masaaki Okabe; Yoshifusa Aizawa
Journal:  Int J Cardiol Heart Vasc       Date:  2018-08-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.